Technibel GRV79R5VAA Technical Data & Service Manual page 7

Table of Contents

Advertisement

Indoor Unit
MCAV97R5VAA
Outdoor Unit
GRV99R5VAA
Power Source
Voltage rating
Performance
Capacity
Air circulation (High)
Moisture removal (High)
Electrical Rating
Available voltage range
Running amperes
Power input
Power factor
C.O.P.
Compressor locked rotor amperes
Features
Controls / Temperature control
Control unit
Timer
Fan speeds
Airflow direction (Indoor)
Air filter
Compressor
Refrigerant / Amount charged at shipment
Refrigerant control
Operation sound
Refrigerant tubing connections
Max. allowable tubing length at shipment
Refrigerant
tube diameter
Refrigerant tube kit / Accessories
Dimensions & Weight
Unit dimensions
Package dimensions
Weight
Shipping volume
Remarks:
Rating conditions are:
Cooling :
Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
Heating :
Indoor air temperature 20°C D.B.
Outdoor air temperature 7°C D.B. / 6°C W.B.
BTU/h
Liters/h
Indoor / Outdoor
Horizontal
Vertical
Indoor : Hi / Me / Lo
Outdoor : Hi
Narrow tube
mm (in.)
Wide tube
mm (in.)
Height
Width
Depth
Height
Width
Depth
Net
Shipping
Cooling
kW
2.65
9,037
3
m
/h
0.8
Cooling
V
A
4.7
W
1030
%
95
W/W
2.6
A
24
Microprocessor / I.C. thermostat
ON/OFF 24 hours & Daily program,1-hour OFF
g
dB-A
37 / 32 / 31
dB-A
43
m
Indoor Unit
mm
270
mm
805
mm
177
mm
243
mm
855
mm
332
kg
8.0
kg
10.0
3
m
0.07
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
3
220–240V ~ 50Hz
230 V
430
198 ~ 264
Wireless remote control unit
3 and Auto / 1(Hi)
Manual
Auto
Washable, Anti-Mold
Rotary (Hermetic)
R407c / 990
Capillary tube
37 / 32 / 31
Flare type
7.5
6.35(1/4)
9.52(3/8)
Optional / Air Clean Filter
Outdoor Unit
Heating
3.5
11,93
Heating
4.6
1050
96
3.4
24
45
540
700
265
568
815
343
36.0
39.0
0.16

Advertisement

Table of Contents
loading

Table of Contents