Technibel GRV79R5VAA Technical Data & Service Manual page 32

Table of Contents

Advertisement

Indoor Unit
MCAV127R5VAA
Outdoor Unit
GRV129R5VAA
230V Single Phase 50Hz
RATING CAPACITY
AIR FLOW RATE
EVAPORATOR
ENT.TEMP. °C
W.B.
15
17
19
21
23
TC:
TOTAL COOLING CAPACITY
SHC:
SENSIBLE HEAT CAPACITY
CM:
COMPRESSOR INPUT
RATING CONDITIONS
OUTDOOR AMBIENT TEMPERATURE
INDOOR UNIT ENTERING AIR TEMP.
3.3 kW
430 m³/h
D.B.
TC
CM
21
SHC
23
SHC
25
SHC
27
SHC
29
SHC
31
SHC
TC
CM
21
SHC
23
SHC
25
SHC
27
SHC
29
SHC
31
SHC
TC
CM
21
SHC
23
SHC
25
SHC
27
SHC
29
SHC
31
SHC
TC
CM
23
SHC
25
SHC
27
SHC
29
SHC
31
SHC
TC
CM
25
SHC
27
SHC
29
SHC
31
SHC
CONDENSER
OUTDOOR AMBIENT TEMP. °C
25
30
3.13
3.03
0.85
0.90
2.14
2.10
2.43
2.38
2.71
2.65
2.99
2.93
3.13
3.03
3.13
3.03
3.39
3.26
0.87
0.93
1.88
1.82
2.16
2.09
2.44
2.37
2.72
2.65
3.01
2.93
3.29
3.20
3.59
3.47
0.91
0.96
1.57
1.52
1.85
1.80
2.12
2.07
2.39
2.35
2.65
2.63
2.93
2.91
3.80
3.67
0.93
0.99
1.55
1.50
1.82
1.77
2.09
2.05
2.36
2.32
2.63
2.60
4.06
3.89
0.95
1.01
1.52
1.46
1.78
1.73
2.05
2.01
2.34
2.29
kW
kW
kW
35°C D.B.
27°C D.B./19°C W.B.
28
35
40
2.89
2.71
0.97
1.07
2.03
1.94
2.31
2.22
2.58
2.50
2.86
2.71
2.89
2.71
2.89
2.71
3.10
2.91
1.00
1.10
1.75
1.66
2.02
1.94
2.30
2.22
2.58
2.49
2.86
2.77
3.10
2.91
3.30
3.10
1.03
1.13
1.45
1.36
1.73
1.64
2.00
1.92
2.28
2.20
2.55
2.48
2.83
2.75
3.50
3.29
1.06
1.16
1.43
1.34
1.71
1.62
1.98
1.90
2.26
2.17
2.53
2.45
3.67
3.44
1.09
1.19
1.38
1.29
1.65
1.56
1.93
1.84
2.20
2.12
43
2.50
1.16
1.84
2.12
2.40
2.50
2.50
2.50
2.68
1.19
1.56
1.84
2.11
2.39
2.66
2.68
2.86
1.22
1.26
1.54
1.82
2.09
2.37
2.65
3.03
1.26
1.24
1.52
1.79
2.07
2.35
3.20
1.29
1.21
1.48
1.76
2.04

Advertisement