Outdoor Unit
AVOID:
heat sources, exhaust fans, etc. (Fig. 3)
damp, humid or uneven locations.
DO:
choose a place as cool as possible.
choose a place that is well ventilated.
allow enough room around the unit for air
intake/exhaust and possible maintenance.
(Figs. 4b and 4c)
provide a solid base (concrete block, 10
beams or equal), a minimum of 10 cm above ground
level to reduce humidity and protect the unit against
possible water damage and decreased service life.
(Fig.5b)
use lug bolts or equal to bolt down unit, reducing
vibration and noise.
Required space around the unit.
Min.
5 cm
Air intake
Min. 10 cm
Min.
Air discharge
40 cm
Top View
Top View
Fig. 4b
Air intake
Concrete
or equal
Outdoor unit
40 cm
Obstacle above
Valve
side
Min. 25 cm
Fig 4 C
Fig. 5b
40
NO
Hot air
Fig. 3
Fig. 3
2 m
2 m
Ground
Side View
Fig. 4c
Anchor bolts
(4 pcs.)
Min. 10 cm
Exhaust fan
Heat source