2.3 Battery Supply Operation - Baudcom BD-FS-30 User Manual

Optical fiber fusion splicer
Table of Contents

Advertisement

2.2.2 The AC/DC adapter will not be able to supple normal DC output if the
input AC voltage is lower than 100V or higher than 240V. At this
situation, the DC output line of the adapter must not be inserted into
"POWER INPUT "specified on the power module of the Fusion
Splicer, otherwise it will results in the damage of fusion splicer.
2.2.3 If lithium battery is arranged in the battery case, the battery pack will
also be charged when the adapter is supplying power. However, it is
recommended that the Fusion Splicer be shut when charged.
2.3 Battery supply operation
The user may choose to use the polymer lithium battery in the splicer to
separately supply for the Fusion Splicer.
2.3.1 Checking of battery capacity
When the power module is not in the charged state, press the "PUSH"
button on the flank of the power module. Then the four battery capacity
indicator (red) lights on the left side will be bright. The number of the lit
light represents the highness or lowness of the battery capacity. See the
following table.
Website: www.baudcom.com.cn
OUTPUT: DC13.5V ∕ 5A
Tel: +86 21 37709251
Email: info@baudcom.com.cn