External Output Trigger State: The drop down box gives you the option to disable the
external output signal or make the signal dependant on active states of either the
photocell or External Input or a combination of the two. (Photocell Active State =
Darkness. External Input Active State = Valid Trigger received. )
The External Output active state, provided above conditions are met, can be selected
to be open / high or closed / low.
Note: External Output is triggered by the local illuminator Photocell and the local
illuminator External Input only.
Factory Default:
Factory Default:

Photocell Sensitivity

The photocell switch-on level can be altered using the slider bar.
Levels are:
Minimum level =
Maximum level =
Factory Default:
There is a high level of hysteresis and an in-built delay incorporated to avoid
switching ON / OFF in marginal lighting conditions.
WARNING: For changes to take effect, the
Photocell Only
Short Circuit / Low
5 lux
65 lux
20 lux
SAVE
button must be pressed
48