Installation -

Disassemble the camera

Before installing your camera, you have to read the following cautions.
1. The mounting surface must withstand five times the camera weight.
2. Do not let the cables get caught in improper places or the electric line cover can be damaged. This
may cause a short or fire.
3. For the installation process, remove the dome cover from the camera module by loosening the three
(3) screws on the dome. Use the wrench provided with the camera.
4. Install the moisture packet in the base of the camera's lens.
a. Remove the existing packet from the camera's base.
b. Insert the new moisture absorber packet in its place, as seen in the diagram below.
c. Place the moisture absorber under the camera's lens module.
5. Remove the protection film before placing the dome back on the camera. When placing the dome
back on the camera, align the ridge on the dome with the one on the camera's base.
Dome protection
film
Reset to the Factory Default
Press the reset button for 5 seconds to return
the setup to the factory default.
Warning:
If you press the 'Reset' button, you will lose all
setting data. If needed, please, make a note for
further installation.
Warning:
DO NOT TOUCH THE SURFACE OF THE
BUBBLE. CleanView™ Hydrophobic Dome
Coating has been applied to the camera's dome.
Reset button