Westinghouse WFE547 User Manual page 27

540mm and 600mm slot-in upright range cooker
Hide thumbs Also See for WFE547:
Table of Contents

Advertisement

INSTALLATION
Gas requirements
This appliance must be installed by an authorised person,
according to all codes and regulations of:
AS/NZS 5601.1 (particular attention to clause 6.10.1
and figure 6.3 on page 97, and clause 6.10.1.11)
The cookers come in two gas types: Natural gas and
Universal LPG. Before installation check that the cooker
is suitable for the gas supply. To do this check the gas
type on the carton sticker or on the data plate behind the
bottom of the oven door. The following table shows the
supply and operating pressures for various gas supplies.
GAS TYPE
Supply pressure at inlet to
appliance regulator (if fitted)
Operating pressure
at appliance test point for
WFG617
Operating pressure
at appliance test point for
WFE517, WFE616, WFE619
*Some models do not require an appliance regulator
for LPG operation, in which case the supply pressure
and operating pressure are the same. In such cases
the supply pressure is adjusted at a regulator in the
consumer piping, typically located at the cylinder.
The following table shows the injector sizes for each burner.
INJECTOR ORIFICE
NATURAL GAS
Low heat burner
1.00 mm
Medium heat burner 1.35 mm
High heat burner
1.60 mm
Intense heat wok
1.75 mm
burner
Oven – main injector 1.60 mm
Grill
1.50mm
Oven – bypass
0.73mm
screw
Checking pipe size
To work out a suitable pipe size for connection use:
The information in this table.
GAS TYPE
Hourly gas consumption for
WFG617
Hourly gas consumption for
WFE616, WFE619
Hourly gas consumption for
WFE517
Information about the length of the run, number of
elbows, tees and bends, the available service pressure
and the supply requirements.
NOTE: AS/NZS 5601.1 will help you with this matter.
NATURAL
UNIVERSAL
GAS
LPG
1.13 kPa
2.75* kPa
Minimum
1.00 kPa
2.75 kPa
1.00 kPa
2.60 kPa
UNIVERSAL
LPG
0.55 mm
0.70 mm
0.90 mm
1.00 mm
0.82 mm
0.82mm
0.45mm
NATURAL
UNIVERSAL
GAS
LPG
63.3MJ/h
52.4MJ/h
40.4MJ/h
34.4MJ/h
37.3 MJ/h
30.2MJ/h
27
INSTALLATION

Advertisement

Table of Contents
loading