Step 3. Preparing Unit For Installation - Monogram ZIRNPKII Installation Instructions Manual

18” and 24”built-in column freezers, 24” and 30” built-in column refrigerators
Table of Contents

Advertisement

Available languages

Available languages

Installation Instructions - Dual Retro-Fit Installation
STEP 2 INSTALL WATER LINE
(Cont.)
NOTE: The only GE Appliances approved plastic tubing
is supplied in the SmartConnect
kits. Do not use any other plastic water supply line
because the line is under pressure at all times. Other
types of plastic may crack or rupture with age and
cause water damage to your home.
Tape the jumper waterline and water fitting tee to the
back wall. The waterlines will be taped to the floor
using masking tape after anti-tip bracket installation.
STEP 3 PREPARING UNIT FOR
INSTALLATION
Place the right hand unit in front of the installation
opening in a way that the unit is in front of the
intended installed location.
Unpack the heater Unification Kit (ZUGC) and make
sure all of the components on the list are included.
Install 4 bumper blocks by snapping them to the left
side of the case between the 2 units - 2 on the upper
section of the case wall and 2 on the lower.
Upper bumpers
Lower bumpers
Refrigerator Tubing
STEP 3 PREPARING UNIT FOR
INSTALLATION (Cont.)
Install adhesive heater on the outside of the unit to
the left side of the case. Install heater 2" below the top
2 standoff blocks. Heater should be centered front to
back on the metal case. Ensure the heater connector
cord is toward the bottom of the unit when installed.
Clips
Remove the left access cover by removing 4 (1/4")
hex screws. The cover is located at the outside lower
left side of the case.
Use clips to adhere loose wire tightly to side of case
as shown. Clean the side using rubbing alcohol to
ensure proper clip adhesion.
22
Adhesive
Heater
Left Access
Hex
Cover
Screws
31-49133-1

Advertisement

Table of Contents
loading

This manual is also suitable for: