Design Guide - Dual Integrated Installation
DUAL INTEGRATED INSTALLATION SPACE
Dimensions in parentheses are in centimeters.
18" Integrated Freezer
24" Integrated Refrigerator
41 1/2"
84"
27 1/4"
(213.4)
(69.2)
22 1/8"
(56.2)
7 1/2"
(19.1)
2"
(5.1)
4 1/8"
(10.5)
6 3/4"
4"
E W
(17.2)
(10.2)
3 1/2"
2 1/2"
(8.9)
(6.4)
FRONT VIEW
18" Integrated Freezer
30" Integrated Refrigerator
47 1/2"
(120.7)
84"
28"
(71.1)
(213.4)
22 1/8"
(56.2)
7 1/2"
(19.1)
2"
(5.1)
4 1/8"
(10.5)
6 3/4"
4"
E W
ELEC W
(17.2)
(10.2)
3 1/2"
2 1/2"
(8.9)
(6.4)
FRONT VIEW
Water And Electrical Locations
Electrical and water supply must be located as shown.
The Cutout Depth Must Be 25"
Cutout is based on installation of 2 products with a left-
and-right hand door swing.
Heater Unification Kit ZUGC required.
Product Clearances
These units are equipped with a 2-position door stop.
The factory set 115° door swing can be adjusted to 90°
if clearance to adjacent cabinets or walls is restricted.
For a 90° door swing, allow 4" (10.2 cm) minimum
clearance to a wall.
When installed in a corner, allow 15" (38.1 cm) for a full
115° door swing on 18" and 24" models. Allow 16.5"
(41.9 cm) on 30" models.
31-49133-1
(105.4)
3 1/2"
(8.9)
Finished
Return
4"
(10.2)
6 3/4"
ELEC W
(17.2)
5"
2 1/2"
(12.7)
(6.4)
25"
3 1/2"
(8.9)
Finished
Return
6 1/4"
(10.2)
6 3/4"
(17.2)
5"
2 1/2"
(12.7)
(6.4)
SIDE VIEW
24" Integrated Freezer
24" Integrated Refrigerator
25"
(63.5)
84"
(213.4)
9 1/2"
(24.1)
4 3/8"
(11.1)
ELEC W
SIDE VIEW
24" Integrated Freezer
30" Integrated Refrigerator
(63.5)
84"
84"
(213.4)
9 1/2"
(24.1)
4 3/8"
(11.1)
ELEC W
Additional Specifications
• A separate 115 volt 60Hz., 15 or 20 amp power supply
is recommended for each product. An individual
properly grounded branch circuit or circuit breaker is
recommended. Install a properly grounded 3-prong
electrical receptacle recessed into the back wall.
Electrical must be located on rear wall as shown.
• Water line must be located on the back wall as shown.
The water line should be 1/4" O.D. copper tubing or
QuickConnect
water line and water connection location, long enough
to extend to the front of the unit (8' [2.4m]). Installation
of an easily accessible shut-off valve in the water line
is required.
• A minimum of 3-1/2" finished return matching cabinet
exterior is recommended on interior on all sides and
top at front of opening.
7
47 1/2"
(120.7)
4"
33 1/4"
(84.5)
(10.2)
28 1/8"
(71.4)
4
6 3/4"
6 3/4"
ELEC W
(17.2)
(17.2)
5"
2 1/2"
5"
2 1/2"
(12.7)
(6.4)
(12.7)
(6.4)
FRONT VIEW
53 1/2"
(134.6)
6 1/4"
34"
(15.9)
(86.4)
28 1/8"
(71.4)
6 3/4"
6 3/4"
ELEC W
(17.2)
(17.2)
5"
2 1/2"
5"
2 1/2"
(12.7)
(6.4)
(12.7)
(6.4)
FRONT VIEW
kit (WX08X10006) between the cold
25"
(63.5)
3 1/2"
(8.9)
Finished
Return
SIDE VIEW
25"
25
(63.5)
3 1/2"
(8.9)
Finished
Return
SIDE VIEW