4. Refrigerant System Diagram
INDOOR UNIT
HEAT
EXCHANGE
(EVAPORATOR)
Connection pipe specification:
Liquid : 1/4
Gas : 1/2
10
GAS SIDE
3-WAY VALVE
Discharge
Suction
COMPRESSOR
LIQUID SIDE
Electron
Strainer
2-WAY VALVE
expansion
valve
OUTDOOR UNIT
4-Way valve
Accumlator
HEAT
EXCHANGE
(CONDENSER)
Intercooler
Strainer
Strainer
Capillary
Service Manual
Strainer
COOLING
HEATING
Technical Information