 Sample Type
 Value
 Startup Alarm
 Rising Threshold
 Rising Index
 Falling Threshold
 Falling Index
Buttons
: Click to add a new community entry.
: Click to apply changes
:
Click to undo any changes made locally and revert to previously saved values.

4.2.3.2 RMON Alarm Status

This page provides an overview of RMON Alarm entries. Each page shows up to 99 entries from the Alarm table, default being
20, selected through the "entries per page" input field. When first visited, the web page will show the first 20 entries from the
beginning of the Alarm table. The first displayed will be the one with the lowest ID found in the Alarm table; screen in
User's Manual of GS-5220-24T4XV(R) Managed LCD Switch
InUnknownProtos: the number of the inbound packets that is discarded
because of the unknown or un-support protocol.
OutOctets: The number of octets transmitted out of the interface, including
framing characters.
OutUcastPkts: The number of uni-cast packets that requests to transmit.
OutNUcastPkts: The number of broadcast and multi-cast packets that
requests to transmit.
OutDiscards: The number of outbound packets that is discarded even the
packets are normal.
OutErrors: The number of outbound packets that could not be transmitted
because of errors.
OutQLen: The length of the output packet queue (in packets).
The method of sampling the selected variable and calculating the value to be
compared against the thresholds; possible sample types are:
Absolute: Get the sample directly.
Delta: Calculate the difference between samples (default).
The value of the statistic during the last sampling period.
The method of sampling the selected variable and calculating the value to be
compared against the thresholds; possible sample types are:
RisingTrigger alarm when the first value is larger than the rising threshold.
FallingTrigger alarm when the first value is less than the falling threshold.
RisingOrFallingTrigger alarm when the first value is larger than the rising
threshold or less than the falling threshold (default).
Rising threshold value (-2147483648-2147483647).
Rising event index (1-65535).
Falling threshold value (-2147483648-2147483647)
Falling event index (1-65535).