Lincoln Electric POWER FEED 10 A Operator's Manual page 36

Table of Contents

Advertisement

E-6
PROBLEMS
(SYMPTOMS)
Wire feed speed consistently oper-
ates at the wrong value.
Variable or "hunting" arc.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
All manuals and user guides at all-guides.com
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE
OUTPUT PROBLEMS
1. The wire feeder gear setting is
not properly set. Verify the soft-
ware setting matches the gear
mounted. See the Instruction
Manual for setting the gear
speed.
1. Wrong size, worn and/or melted
contact tip. Replace the contact
tip.
2. Worn work cable or poor work
connection. Verify all work and
electrode connections are tight
and that the cables are in good
condition. Clean/replace as nec-
essary.
3. Wrong polarity. Adjust polarity to
the recommended procedure.
Verify DIP switch #7 setting
matches the electrode polarity.
POWER FEED™ 10A CONTROLLER
CAUSE
If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.
CAUTION
RECOMMENDED
COURSE OF ACTION
E-6

Advertisement