B-11
P.21
Shutdown2 Select
• Press the right Mode Select Button.
• Turn the Knob to toggle between Standard
Shutdown or Output Lockout.
This option allows the user to use the shutdown 2
input on the control box to lock the welding output in
the OFF state, but still allow cold feeding of the wire.
Standard Shutdown = Default behavior, normal shut-
down mode prevents cold feed of wire.
Output Lockout = Allows cold feed of wire and pre-
vents the activation of welding output.
• Pressing the left Mode Select Panel Pushbutton will
exit the parameter setting section, returning to the
previous section. Continuing to press the left Mode
Select Panel Pushbutton will return to the Setup
Mode user preferences and welding parameters list.
• Diagnostic tools SHOW TEST MODES and VIEW
DIAGS can be accessed in the Mode Select Panel
Setup Mode also, but these tools should only be
accessed by properly trained personnel.

INFRARED (IR) CONTROL

The Mode Select Panel interface includes an infrared
transceiver. This allows wireless machine configura-
tion using a Palm OS based handheld computer. A
proprietary Palm OS application, ALPalm, has been
developed for this purpose.

LOCKOUT/SECURITY

The Power Feed 10A can be optionally configured to
prevent the operator from changing selected Power
Feed 10A panel controls. By default, the welder will
be able to change the weld mode, all relevant wave
controls and all relevant start and end options.
All manuals and user guides at all-guides.com
OPERATION
Standard
Shutdown
POWER FEED™ 10A CONTROLLER
Here is a list of Lockout levels:
PANEL
All Mode Select options unlocked (default).
All Mode Select options locked.
START OPTIONS and END OPTIONS
locked.
WELD MODE selection locked, only wave
controls are unlocked (useful when Memory)
Mode Select
Panel is used to recall weld modes.
AC CONTROL locked.
START OPTIONS, END OPTIONS, and
wave options locked.
START OPTIONS, END OPTIONS, and
WELD MODE locked.
All memories enabled (default).
All memories disabled.
Memories 2-6 disabled.
Memory Panel
Memories 3-6 disabled.
Memories 4-6 disabled.
Memories 5-6 disabled.
Memory 6 disabled.
Both knobs unlocked (default).
Both knobs locked.
Encoder Panel
Right knob locked.
Left knob locked.
Note that when an option is locked, its value can still
be monitored. For example, if start and end options
are locked, the welder can still press the right Mode
Select Panel Pushbutton and see the value set for
Start Time. If the welder attempts to change its value,
a message will briefly appear on the Mode Select
Panel indicating "MSP Option is LOCKED!".
Presently, lockout features are only available
through a PC application or the IR Port.
B-11