Microchip Technology Protouch2 User Manual page 8

Command line interface
Hide thumbs Also See for Protouch2:
Table of Contents

Advertisement

Protouch2 CLI User Manual
To get the winusb handle from the HFC, PID needs to be added to the following
list. Vendor ID of the HFC will be taken from "HUB_VID_LIST" section (Refer
section
3.1).Following listed Product ID's are default one and if any of the HFC
device has different PID's except below listed values , those need to be added into the
list.
Example:
[HCE_DEV_INFO]
HCE_PID1 = 0x2530;
HCE_PID2 = 0x2740;
HCE_PID3 = 0x274E;
HCE_PID4 = 0x274F;
; VID of the HFC will be taken from "HUB_VID_LIST" section
Maximum entry is 10. (Max is HFC_PID10 = 0x1234 and HFC_PID11 = 0x1234 is
not valid one)
 2016 Microchip Technology Inc