Badger Meter 228PV Series Installation & Operation Manual

Badger Meter 228PV Series Installation & Operation Manual

Plastic tee type wireless flow sensor
Hide thumbs Also See for 228PV Series:

Advertisement

Installation &
Plastic Tee Type
Series 228PV
Operation Manual
Wireless Flow Sensor
BadgerMeter, Inc.
880024
3-07
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 228PV Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Badger Meter 228PV Series

  • Page 1 Installation & Plastic Tee Type Series 228PV Operation Manual Wireless Flow Sensor BadgerMeter, Inc. 880024 3-07 ®...
  • Page 2: Table Of Contents

    Sensor System Matrix. could be damaged. Badger Meter flow sensors are designed to operate reliably under adverse conditions, but the following Series 228PV Wireless Flow Sensor...
  • Page 3: Installation

    Antenna Power Supply Pulse Output Valve Box Cover Wireless Transmitter 5’ Cable Flow Sensor FLOW Minimum Distance Minimum Distance 10 x I.D. 5 x I.D. Typical Wireless Flow Sensor Installation Wireless Series 228PV Plastic Tee Sensor Mechanical Installation Threaded Note intended direction of flow as indicated by arrows on the tee.
  • Page 4 Antenna kits are an optional accessory and can be ordered by specifying the appropriate model number from the Sensor Selection Matrix. Badger Meter offers two different antenna P/N: 820057-0001 kits: the A355LP low profile antenna kit and the A355 whip 8"...
  • Page 5: Theory Of Operation

    Made in USA Note: Figure 6: Sample Badger ORION Wireless Receiver The Badger Meter Model A301W cable will work with all Electrical Wiring Series 300 products. However the older version of the Refer to Figure 6 for terminal connections and wiring cable (A300) does not have sufficient bandwidth to work example.
  • Page 6: Wireless Receiver Programming

    WIRELESS RECEIVER PROGRAMMING To change settings in the wireless receiver, Badger Meter Select configuration and open the Set Comm Port screen software must be installed and the new values entered using to set the appropriate comm port for the A301W cable as shown in the dialog boxes below.
  • Page 7: Wireless Sensor Programming

    Open the Parameters screen. Badger Meter sensors will operate both above and below the suggested flow range for each tee size. Test results have shown, however, that the highest accuracy and best repeat- ability are achieved in this flow range.
  • Page 8: Specifications

    BadgerMeter, Inc. Please see our website at www.dataindustrial.com 6116 E. 15th Street, Tulsa, Oklahoma 74112 for specific contacts. (918) 836-8411 / Fax: (918) 832-9962 www.dataindustrial.com Copyright © Badger Meter, Inc. 2007. All rights reserved. ®...

Table of Contents