Page 2
Tel: +43 (0) 7249 / 46 443 www.austroflamm.com info@austroflamm.com Edited by: Olivera Stojanovic Illustrations: Konstruktion Text: Technical department (Austroflamm) Copyright All Rights reserved. The contents of these instructions may be reproduced or distributed only with the consent of the publisher! Printing, spelling and typographical errors reserved.
Operating manual Dexter S3 2.0 945065 Contents Contents General information ............................Copyright.............................. Purpose of the manual ............................Storing the manual ..........................Structure of the manual........................Representations used.......................... Version control............................. Abbreviations ............................Safety ..................................Importance of the safety instructions ....................Warning of sources of danger ......................
Page 4
Contents Operating manual Dexter S3 2.0 945065 9.2.3 Mounting the Keramott........................25 9.2.4 Installing the HMS..........................26 9.2.5 Mounting the shadow joint ........................ 26 9.2.6 Mounting the side boxes ........................27 10 Settings................................. 28 10.1 Adjusting the door handle and the lock................... 28 10.2...
Operating manual Dexter S3 2.0 945065 1 | General information General information You have decided in favor of an Austroflamm stove. Congratulations on your decision and thank you for your trust. Correct operation and care are essential for trouble-free operation and long service life.
2 | Purpose of the manual Operating manual Dexter S3 2.0 945065 Purpose of the manual This manual is a component part of the stove and is intended to contribute to the stove being safely in- stalled and maintained. Please read this manual before using the stove for the first time.
3 | Safety Operating manual Dexter S3 2.0 945065 Safety In this manual we give you numerous safety instructions for the safe operation of your stove. These in- structions are characterized differently as follows, depending on their importance: Importance of the safety instructions NOTICE Particular behaviour and/or activities that are required for safe working.
Operating manual Dexter S3 2.0 945065 3 | Safety • Please note that the surfaces of this stove heat up considerably during operation. We recommend that you use the protective glove supplied to operate your stove. • Please alert children to these dangers, and keep them away from the stove when it is operating.
Operating manual Dexter S3 2.0 945065 Product overview Intended use The Austroflamm stove described in this manual is manufactured and tested with a type A1 self-closing and locking door under EN test EN 13240. NOTICE Operation is only permissible with closed/bolted door.
Page 11
Operating manual Dexter S3 2.0 945065 4 | Product overview 1) Open (+) and closed (-) (primary/secondary air control- ler) Fig. 2: Air control Safety distances Fig. 3: Safety distances for corner set-up Fig. 4: Safety distances for wall set-up...
4 | Product overview Operating manual Dexter S3 2.0 945065 Energy label -80% Austrof amm Dexter S3 -60% -40% -20% ENERGIA · ЕНЕРГИЯ · ΕΝΕΡΓΕΙΑ · ENERGIJA · ENERGY · ENERGIE · ENERGI 2015/1186 Fig. 5: Energy label Positioning of the nameplates Here we show where you can find the nameplate.
Operating manual Dexter S3 2.0 945065 5 | Technical data Technical data As a type 1 stove, a connection to a chimney already occupied with other solid-fuel stoves and ovens is possible provided that the chimney rating under DIN 4705 – part 3, does not contravene this.
Page 14
5 | Technical data Operating manual Dexter S3 2.0 945065 Lignite briquettes Peat briquettes Briquettes made from a mixture of fossil fuels Other fossil fuels Briquettes made from a mixture of biomass and fossil fuels Other mixture of biomass and solid fuels (*) PM = dust, OGC = organic gaseous connections, CO = carbon monoxide, NOx = nitrogen oxide (**) Only required when using correction factors F(2) or F(3).
Operating manual Dexter S3 2.0 945065 5 | Technical data Specification mg/m³ for heated filter method (in compliance with Annexe III, number 4, letter a, sec- tion i, point 1) or g/kg for measurement in dilution tunnel (in compliance with Annexe III, number 4, let- ter a, section i, point 2 and 3.)
6 | Transport, handling and storage Operating manual Dexter S3 2.0 945065 Transport, handling and storage Transportation Immediately checked the goods delivered for complete- ness and damage in transit. Before installing the stove, check that all movable parts are working. Any defects before the installation of the stove must be reported.
When connecting the flue pipes to the chimney, national and/or local safety regulations must be com- plied with. Your Austroflamm stove is fitted at the factory with a flue pipe outlet at the top (diameter 150 mm). The connection can, as described in these instructions, be rearranged to the bottom. When connecting with other pipe diameters the approval of your responsible chimney sweep is required.
7 | Requirements at the installation location Operating manual Dexter S3 2.0 945065 Floor load-bearing capacity Before installing, verify whether the load-bearing capacity of the substructure can withstand the weight of your Austroflamm stove. Floor condition In the radiation area of the pane (in front of the stove), the floor must not be combustible.
Operating manual Dexter S3 2.0 945065 8 | Fuel material/-quantity Fuel material/-quantity Fuel Wood Many of our native types of wood can, after being appropriately dried, be burnt CO2-neutral in heat- producing appliances. Wood stands out because it grows again, can be sustainably harvested, re- quires little or no extra external energy to be invested in the fuel, and has a short journey from the pro- ducer to the consumer, which provides an optimal climate balance.
Page 20
8 | Fuel material/-quantity Operating manual Dexter S3 2.0 945065 Please observe at all times the maximum specified amount to be laid, even when putting on more wood! Otherwise your fire will not provide the desired efficiency - but above all considerable damage may be caused to your appliance, to gaskets and material and to the flue gas duct.
Maximum amount of fuel to be deposited: 1.4 kg wood. NOTICE Overheating Too great a quantity of fuel can lead to overheating and damage to your Austroflamm stove NOTICE To avoid damage you must NEVER operate your Stove a greater quantity of fuel than that specified in...
9 | Installation Operating manual Dexter S3 2.0 945065 Installation Installation must only be carried out by an authorized specialist company. Before installing the stove, check that all movable parts are working. Any defects must be reported be- fore the installation.
Page 23
Operating manual Dexter S3 2.0 945065 9 | Installation 2) Use a saw to remove the perforated cut-out in the rear panel. Fig. 11: Removing the perforated cut-out 3) Dismantling the cover with the seal (1) on the rear panel. 4) Dismantling the bracket with the seal (2).
Page 24
9 | Installation Operating manual Dexter S3 2.0 945065 5) Replace parts and reinstall. Fig. 13: Replace the cover and bracket 6) Remount the rear panel. Fig. 14: Installing the rear panel...
Operating manual Dexter S3 2.0 945065 9 | Installation 9.2.2 Installing the air supply adapter 1) Dismantle the rear panel inspection door (1). Fig. 15: Dismantling the rear panel inspec- tion door 2) Mount the air supply adapter (1) with the clamp to the supply air connection (2) and fasten with the screws to the stove.
9 | Installation Operating manual Dexter S3 2.0 945065 2) When installing the last two Keramott bricks, they must be installed on the tension plate support. ð The tension plate support and the Keramott stone must be joined without a gap. Tighten the screws accordingly.
Operating manual Dexter S3 2.0 945065 9 | Installation 9.2.6 Mounting the side boxes 1) The side boxes can be added individually to the stove. Fig. 21: Placing the side boxes next to it...
10 | Settings Operating manual Dexter S3 2.0 945065 Settings 10.1 Adjusting the door handle and the lock 1) Open the door. Fig. 22: Opening the door • Dismantling the screws (1) and the folding handle plates Fig. 23: Setting the handle...
Page 29
Operating manual Dexter S3 2.0 945065 10 | Settings • Use the grub screw (3) to adjust the handle. • Reinstall the folding handle plates (2). Fig. 24: Setting the handle 2) Use the screws (1) to adjust the lock (2).
10 | Settings Operating manual Dexter S3 2.0 945065 10.2 Adjusting the door 1) Open the door. Fig. 27: Opening the door 2) The marked screws can be used to adjust the door forward, backward, upward or downward direction. Fig. 28: Adjusting the door with screws 10.3 Tensioning the door spring...
Page 31
Operating manual Dexter S3 2.0 945065 10 | Settings 3) Release the spring (1). 4) Remove the door tensioner (2) and insert it at the spring (1) and keep it there. Fig. 30: Releasing the spring 5) Secure the spring (1).
11 | Commissioning Operating manual Dexter S3 2.0 945065 Commissioning 11.1 Initial Commissioning NOTICE During the initial commissioning and in the following 2-3 combustion cycles, only approx. 2/3 of the maximum fuel quantity is to be used. NOTICE To avoid damage you must NEVER operate your Stove a greater quantity of fuel than that specified in this manual! During the first 3-4 combustion cycles at nominal heat output, odors may develop.
Operating manual Dexter S3 2.0 945065 12 | Operation Operation 12.1 Before heating up The stove can only function properly if there is sufficient combustion air coming to the room of installa- tion (the appliance), specially if several firing installations are being operated at the same time. Ensure sufficient air supply before heating up.
12 | Operation Operating manual Dexter S3 2.0 945065 7) Close the door. ð It is best to allow the first layer of wood to combust without altering the air damper setting. ð If only the bed of embers is left (no more flames), you can place another layer of log.
Operating manual Dexter S3 2.0 945065 13 | Maintenance Maintenance 13.1 Changing the seal on the door 1) Remove old seal from the door. 2) Glue in new seal with a suitable adhesive (e.g. silicon B310). Fig. 36: Changing the seal...
14 | Cleaning Operating manual Dexter S3 2.0 945065 Cleaning 14.1 Cleaning the stove, flue gas ducts and flue pipe The stove, the flue gas ducts and flues should be annually - possible even more often, e.g. • after the chimney has been cleaned •...
14.3 Cleaning the door window Spray window with glass cleaner and leave it for a moment to take effect. • We recommend cleaning the glass with our Austroflamm glass cleaner or a commercially available window cleaner. • Prevent door- or window seals from coming into contact with water or cleaner, since these will oth- erwise harden and in doing so lose their function.
15 | Help Operating manual Dexter S3 2.0 945065 Help Problem Cause Solution The glass window is sooty Insufficient draft from time to time (depending on use) the window must be cleaned with glass cleaner Clarification with chimney sweeper (poss extend chimney/measure...
Operating manual Dexter S3 2.0 945065 15 | Help Problem Cause Solution Operating temperature not reached Bring stove to the operating temper- ature Sooting up of the window after 8- 10 hours of fires is normal Chimney draft too low Contact chimney sweep 15.1 Firebox lining...
16 | Accessories Operating manual Dexter S3 2.0 945065 Accessories Have defective parts (accessories, spare parts) replaced by your specialist stove dealer. This guaran- tees that stove is and remains safe and functional.
Page 43
Operating manual Dexter S3 2.0 945065 17 | Spare parts Door Item no. Quantity Item Item no. Door glass panel, front 724486 Door glass panel, side 724487 Hollow round seal Ø 12 718234 Door, complete 724570 Oval seal 718763 Door handle...
Page 44
17 | Spare parts Operating manual Dexter S3 2.0 945065 Keramott Item no. Quantity Item Item no. Left corner, rear 724502 Right corner, rear 724503 Left corner, front 724504 Right corner, front 724505 Side panel 724506 Rear panel 724507 Baffle plate, left...
Operating manual Dexter S3 2.0 945065 18 | Dismantling Dismantling For correct uninstallation and dismantling of the stove, contact your Austroflamm specialist dealer. 18.1 Removing the door 1) Secure the spring with an Allen key AF 2.5 mm (1). 2) Unscrew the screw from the door tensioner (2) with an Allen key AF 3 mm.
NOTICE For correct uninstallation and dismantling of the stove, contact your Austroflamm specialist dealer. Electric and electronic components Remove the electric and electronic components from the appliance by dismounting them. These com- ponents must not be disposed of via non-recyclable waste.
Page 47
Operating manual Dexter S3 2.0 945065 19 | Disposal Handles and decorative elements made of metal If present, disassemble or remove handles and decorative elements made of metal and dispose of as metal scrap. Local disposal options must be observed.
For the replaceability of the warranty case the start-up log must be received by Austroflamm within one month at the latest of the initial commissioning. In or- der to make a claim on the warranty, repairs to your stove must only be carried out by a service en- gineer authorized by Austroflamm.
If you consent to the appropriate handling of your personal data for the following purposes, please tick this box. o I hereby agree that Austroflamm GmbH and AUSTROFLAMM Service GmbH & Co KG may send me service reminders and offers on other products from Austroflamm GmbH for the purposes of advert- ising via E-Mail/ SMS/ telephone.
22 | Start up log Operating manual Dexter S3 2.0 945065 Start up log Operator / Customer Dealer / Engineer Name Company Street Street Town and postal code Town and postal code Telephone Telephone Email Email Stove Working Comments Model...
Page 54
Vollständigkeit / completeness / completo / complet Geprüft von / checked by / controlled da / contrôlé par ____________________________________________________ Datum / date / data / date ____________________________________________________ AUSTROFLAMM GMBH Austroflamm-Platz 1 A- 4631 Krenglbach Tel: +43 (0) 7249 / 46 443 www.austroflamm.com...