Efficiency
100
90
80
70
60
2
50
40
30
20
10
0
0,00 0,25 0,50
Ambient conditions
Ambient temperature (operation)
The ambient temperature (operation) refers to IEC 61010 surrounding air temperature.
Ambient temperature (start-up type tested)
Ambient temperature (storage/transport)
Max. permissible relative humidity (operation)
Installation height
Vibration (operation)
Shock
Degree of pollution
Climatic class
Overvoltage category
EN 61010-1
Standards
Electrical safety (of control and regulation devices)
Protective extra-low voltage
Mains variation/undervoltage
EMC requirements, power plant
110257_en_00
1
:
= U
12 V DC/U
: 24 V DC
1
In
Out
:
= U
24 V DC/U
: 24 V DC
2
In
Out
0,75 1,00
1,25 1,50 1,75 2,00
I
[A]
Out
-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
-40 °C
-40 °C ... 85 °C
≤ 95 % (at 25 °C, non-condensing)
≤ 5000 m (> 2000 m, observe derating)
< 15 Hz, ±2.5 mm amplitude; 15 Hz ... 100 Hz: 2.3 g 90 Min. (in
accordance with IEC 60068-2-6)
18 ms, 30g, in each space direction (according to IEC 60068-
2-27)
2
3K3 (in acc. with EN 60721)
II (≤ 5000 m)
IEC 61010-1
IEC 61010-1 (SELV)
EN 61000-4-29
EN 61850-3
EN 61000-6-5
QUINT4-PS/12-24DC/24DC/1.3/SC
24 V DC
typ. 91.7 %
PHOENIX CONTACT