PARAMOUNT BED PA-8200 Series Instruction Manual

PARAMOUNT BED PA-8200 Series Instruction Manual

Multiple medical recliner

Advertisement

Quick Links

INSTRUCTION MANUAL
7A10708900A1
Thank you for purchasing the PA-8200 Series Recliner.
This instruction manual describes precautions and how to safely use and operate
the recliner.
●Before using this recliner, please read this instruction manual
●The correct operating procedures should be explained not
●After reading this instruction manual, store it where it can be
●The actual product purchased may differ from detailed
●Users and/or carers are requested to report information about any
●Values in the specification such as working range, dimensions,
●For any queries, please feel free to directly contact Paramount Bed
PARAMOUNT BED CO., LTD
Multiple Medical Recliner
PA-8200 Series
to fully understand the safe and proper operating procedures.
only to the persons using the recliner but also to caregivers.
easily accessed for later reference.
descriptions given in this instruction manual due to
product improvements.
serious incident related to this recliner that occurs within the EU to the
manufacturer and the regulating authority of the member country of
residence. 'Serious incident' means any incident that directly or
indirectly led, might have led or might lead to any the following :
a) The death of a user, carer or other person.
b) The temporary or permanent serious deterioration of a user's,
carer's or other person's state of health.
c) A serious public health threat.
angles and mass are subject to normal manufacturing tolerances.
Besides some exemptions, display purpose words such as
"approximately", "about" etc. are omitted.
or your distributor.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PA-8200 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PARAMOUNT BED PA-8200 Series

  • Page 1 Besides some exemptions, display purpose words such as “approximately”, “about” etc. are omitted. ●For any queries, please feel free to directly contact Paramount Bed or your distributor. PARAMOUNT BED CO., LTD...
  • Page 2: Table Of Contents

    CONTENTS Page INTENDED USE AND FEATURES 1. Intended use 2. Frenquently used functions PART NAMES SAFETY PRECAUTIONS 4-11 INSTALLATION CONNECTING TO THE POWER SUPPLY USING THE RECLINER 1. Armrest 2. Getting on or off the recliner 3. Handheld controller 4. Moving the recliner 5.
  • Page 3: Intended Use And Features

    INTENDED USE AND FEATURES 1. Intended use ■The Multiple Medical Recliner is designed to be used in the treatment of dialysis patients and in the drawing of blood samples from patients at medical institutions. ※Please refer to the SPECIFICATION for the patient target groups, the intended users, and the clinical benefits.
  • Page 4: Part Names

    PART NAMES Seat cushion Backrest P.18 Emergency back- Seat lowering lever Legrest P.14 Armrest P.16 Handheld controller P.17 Base frame Caster Applied part * Part of ME EQUIPMENT that in normal use necessary comes into physical contact with patient for ME EQUIPMENT to perform its function.
  • Page 5: Safety Precautions

    ※After reading this instruction manual, store it in a place that can be easily accessed for later reference. [Safety label] ●Precautions requiring special attention by persons using the recliner are affixed as pictured in the figure. ●If the safety label is removed or defaced, replace it with a new one obtained from Paramount Bed or your distributor.
  • Page 6 SAFETY PRECAUTIONS ■Be careful not to allow any part of the body (especially the head or neck) to slip into the gaps between the moving parts shown below. ●When the head or neck enters the gap, the patient might not be able to withdraw, and there is a risk of injury.
  • Page 7 ■For suitable product directly attached to the recliner such as the IV Pole attachment, or foot rest, use only products approved by Paramount Bed. ●The use of products other than the specified suitable products or products from other companies could create unintended gaps, cause interference between products, or lower stability, resulting in injury or failure of the recliner.
  • Page 8 SAFETY PRECAUTIONS ■When the backrest or leg rest are in the horizontal position, do not rest hands on or sit on their ends. ●Otherwise, the patient could fall off or falling down, resulting in injury. ●These actions may lower the product stability and the recliner could fall off, resulting in injury or the recliner could be damaged.
  • Page 9 ■Do not perform any angle adjustment when the patient is lying face down or on their side (in any posture other than lying face up). ●There is a risk of injury caused by extending the joints backward. ■Do not allow the recliner to be operated by a child aged 12 or under, or someone deemed incapable of comprehending the operation of the recliner.
  • Page 10 ●If recliners are damaged in earthquakes, fires, or floods or other incidents, direct requests for contact Paramount Bed or your distributor. Otherwise, there is a risk of electric shock or fire due to short circuit or current leakage from electrical parts, or injury due to malfunctioning caused by deformation of the recliner.
  • Page 11 ■The recliner should not be used by two or more persons. ●This recliner is designed for use by one person. When used by two or more persons, the recliner could be damaged, possibly causing injury. The maximum user weight allowed on the recliner is 138kg.
  • Page 12 SAFETY PRECAUTIONS ■Check around the recliner before moving the recliner. ●If the recliner hits surrounding objects, the objects or the recliner may be damaged. ■Take care when handling electrical parts such as the handheld controller. ●If care is not taken it could cause the recliner to malfunction, resulting in injury or recliner failure. In addition, there is a risk of electric shock or fire due to a short circuit.
  • Page 13: Installation

    INSTALLATION ■To avoid possible malfunctions, do not install the recliner in the following locations. ●Locations expose to direct sunlight ●Locations near heat sources such as a stove or heater ●Location which is heavily electrically charged such as near an MRI. ●Location that has a high oxygen level ●Locations exposed to excessive amounts of water vapor or oil vapor ●Location that tend to be exposed to high temperatures, high humidity, low temperatures or...
  • Page 14: Connecting To The Power Supply

    CONNECTING TO THE POWER SUPPLY ●Do not connect multiple cables to a single power outlet. if other electrical equipment is plugged into a power outlet or an extension cable and its rated capacity is exceeded, it could cause the cable or plug to overheat, resulting in fire.
  • Page 15: Using The Recliner

    USING THE RECLINER 1. Armrest ■In the chair position, the armrest is used to rest elbows and upper limbs. ■The patient can lower the armrest to flat position when getting on or off the recliner. ■The patient can also use the armrest as side-guard at flat position. Chair position (Armrest up) Chair position (Armrest down) Flat position (Armrest up)
  • Page 16: Getting On Or Off The Recliner

    USING THE RECLINER 2. Getting on or off the recliner Before getting on or off, move the recliner as shown  in the figure on the left. Raise the backrest Lower the leg rest  Lower the armrest and get on or off from this side.
  • Page 17: Handheld Controller

    USING THE RECLINER 3. Handheld controller ●Do not allow the recliner to be operated by a child aged 12 or under, or someone deemed incapable of comprehending the operation of the recliner. If a child aged 12 or under, or someone deemed incapable of comprehending the operation (such as persons with dementia) operates the handheld controller by themselves, there is a risk of unexpected injury such as the body getting caught in the recliner by accident.
  • Page 18: Moving The Recliner

    USING THE RECLINER 4. Moving the recliner ●Lock all four casters at all times except when moving the recliner. The recliner could move when a patient gets into or out of the recliner, possibly causing injury. ●Raise the armrest. There is a risk of injury caused patient fall off from the recliner. ●Do not forcibly move the recliner when casters are locked.
  • Page 19: Emergency Back-Lowering

    USING THE RECLINER 5. Emergency back-lowering function ●When performing the emergency back-lowering operation, take care to prevent body parts from getting caught. When the body parts get caught, there is a risk of injury. In particular, before performing the operation, check that nothing is caught in behind the backrest. ■Manual emergency back-lowering function ●Use the emergency back-lowering lever to lower the backrest rapidly in case of emergency, such as the patient fainting due to anemia or a similar condition or a power failure.
  • Page 20: Usb Port

    Do not apply liquids to this product or put foreign objects inside. If liquid or foreign object entered the inside, please turn off unplug power plug from outlet. If still use it, it may cause a short circuit, fire or electric shock. For any queries, please feel free to directly contact Paramount Bed or your distributor.
  • Page 21: Suitable Product

    IV pole support PC-5103 Foot rest PC-5102 Pillow PE-8201 Roll sheets holder PC-5104 Table PF-8250 ●Suitable product may differ due to specification changes or according to product combinations. For any queries, please feel free to contact Paramount Bed or your distributor.
  • Page 22: Pole (Kc-56A/B, Ec-562), Iv Pole Support (Pc-5103)

    ●Install the IV pole support at (Main frame side) IV pole the position where the arrows (KC-56A/B, are facing each other. EC-562) Hole Positioning label (IV pole side) IV pole support ●For any queries, please feel free to contact Paramount Bed or your distributor.
  • Page 23: Foot Rest (Pc-5102)

    There is two hole on the frame side that can be used to adjust footrest position according to height patient by using knob bolt. Foot rest position adjustment knob bolt ●For any queries, please feel free to contact Paramount Bed or your distributor.
  • Page 24: Pillow (Pe-8201)

    ● Make sure that roll sheet holder pipe, nut and bolt has tighten firmly. If it loose, pipe may fall down, hit the foot and causing injury. Roll sheets Bolt Ø150 580 mm or less After installing Before installing ●Roll sheets is commercial product (not include) For any queries, please feel free to contact Paramount Bed or your distributor.
  • Page 25 ● Do not spill liquids such as drinks on the table or leave anything that contains water. This may cause discoloration, deterioration, and deformation. Wipe off and clean up as soon as get wet. Table Fastening bolt Bracket Column Fixing parts ●For any queries, please feel free to contact Paramount Bed or your distributor.
  • Page 26: Bedside Table

    COMPATIBILITY LIST Bedside Table PF-282A, PF-3100A PF-3110A, PF-3120A PF-3130A Bedside table ●The description in this instruction manual may differ from the actual product due to specification changes. For any queries, please feel free to contact Paramount Bed or your distributor.
  • Page 27: Product Symbol Definitions

    PRODUCT SYMBOL DEFINITIONS ■The symbols below are used for the product. Symbol Description Symbol Description ●Indoor use symbol ●Manufacturer ●Electrical waste ●Date of manucfacture ●See the instruction manual ●CE mark ●Type B applied part ●Applied parts are considered to be: ●Safe working load Upper frame section, Controllers, Side-rails, Headboard and Footboard.
  • Page 28: Regular Inspection And Daily Maintenance

    Inspect for loose parts, the operation of moving parts on the recliner, and the presence of damage regularly.When an irregularity has been noticed or when a detailed inspection is desired, contact Paramount Bed or your distributor. Operation details Inspection items...
  • Page 29 REGULAR INSPECTION AND DAILY MAINTENANCE ■Lubrication (if there is abnormal noise) ●Lubrication is needed if there is abnormal noise. Please feel free to contact Paramount Bed or your distributor to be lubricated. ●The water adhesion to the recliner, or moisture may cause corrosion, abnormal noise or contamination.
  • Page 30: Troubleshooting

    ●The recliner cannot be ●Check if the casters are ●Unlock the caster. moved. locked. ●When requesting repairs or contacting Paramount Bed or your distributor, please provide the number on the product ID label. ■Product ID label location Product ID Label ■Product lifetime The lifetime of this equipment is typically eight (8) years.
  • Page 31: Long-Term Storage

    5. Unplug the power plug from the power outlet and wind the power cable onto the cable storage hook. (See p.13) ●Inspect the product regularly at least once a year, even if it is during storage. Recliner disposal When the PA-8200 series recliner has reached the end of its usable life, discard it according to local standards.
  • Page 32 Made of steel, powder coating Side rail Vinyl leather, Urethane foam Safe working load (*5) 204kgf (2,000N) Service life 8 years (based on Paramount Bed data), excluding comsumable items such as casters. Inclination angle 0°to 75°[+7.5] Back raise Time required 18sec.
  • Page 33 SPECIFICATIONS Range Environmental conditions When transported or stored When in use Temperature -10 to 50℃ 5 to 45℃ Humidity 20 to 90%RH 20 to 90%RH Air pressure 700 to 1,060hPa 700 to 1,060hPa 13 years and older Supported age *Do not use the recliner for children (aged 12 or under) or patient range Patient target weighing more than 138kg.
  • Page 34 Without shield Guidance and Manufacturer's Declaration - Electromagnetic Emissions The PA-8200 Series is intended for use in the following electromagnetic environment. The customer or user of the PA-8200 Series should make sure it is used in such an environment. Emission test...
  • Page 35 Guidance and Manufacturer's Declaration - Electromagnetic Immunity The PA-8200 Series is intended for use within healthcare facility environment. Users or customers must use recliner in this environment. IEC 60601-1-2/EN 60601-1-2 Immunity test Compliance level Test level Static electricity discharge (ESD) Contact discharge: ±8kV...
  • Page 36 Guidance and Manufacturer's Declaration - Electromagnetic Immunity Recliner is intended for use in an electromagnetic environment that used wireless RF transciever. Electromagnetic interference can be prevented by maintaining the minimum distance between RF transciever and recliner depend on the maximum output and frequency of the communication device as recommended below. IEC 60601-1-2 Compliance Maximum...
  • Page 37: Specifications

    SPECIFICATIONS Guidance and Manufacturer's Declaration - Electromagnetic Immunity The PA-8200 Series is intended for use in the following electromagnetic environment. The customer or user of the PA- 8200 Series should make sure it is used in such an environment. IEC 60601-1-2...
  • Page 38: After-Sales Service

    ◼ Consumable parts Casters, handheld controller are consumable parts. 2.Minimum stock availability period Paramount Bed keeps replacement parts (necessary to maintain recliner performance) in stock for at least 8 years after the discontinuation of production. 3.Questions regarding after-sales service For any queries, please feel free to contact Paramount Bed or your distributor.
  • Page 39 NOTES...
  • Page 40 2021-04...