9 Error Message And Trouble Shooting - Delta H5E 220 Operation And Installation Manual

Grid-tie transformerless hybrid inverter
Table of Contents

Advertisement

Error Message and Trouble Shooting
9 Error Message and Trouble Shooting
Message
E01: OFR
E02: UFR
E09: No Grid
E10: UVR
E11: OVR
E13: OVR-Slow
E26: OFR-Slow
E27: UFR-Slow
Possible cause
1. Actual utility frequency is higher
than the OFR setting
2. Incorrect country setting
3. Detection circuit malfunction
1. Actual utility frequency is lower
than the UFR setting
2. Incorrect country or Grid setting
3. Detection circuit malfunction
1. AC breaker is OFF
2. AC plug disconnected
3. Internal fuses are broken
1. Actual utility voltage is higher the
UVR setting
2. Incorrect country or Grid setting
3. Detection circuit malfunction
1. Actual utility voltage is higher
than the OVR setting
2. Incorrect country or Grid setting
3. Detection circuit malfunction
1. Actual utility voltage is over
than the OVR setting
2. Incorrect country or Grid setting
3. Detection circuit malfunction
1. Actual utility frequency is over the
OFR setting
2. Incorrect country or grid setting
3. Detection circuit malfunction
1. Actual utility frequency is under
the UFR setting
2. Incorrect country or Grid setting
3. Detection circuit malfunction
Error
1. Check the utility frequency on the
inverter terminal
2. Check country setting
3. Check the detection circuit inside
the inverter
1. Check the utility frequency on the
inverter terminal
2. Check country & Grid setting
3. Check the detection circuit inside
the inverter
1. Switch on AC breaker
2. Check the connection in AC plug and
make sure it connects to inverter
3. Replace fuses and check all
switching devices in boost &
inverter stages
1. Measure the utility AC voltage to
the inverter terminal.
2. Check country & Grid setting
3. Check the detection circuit inside
the inverter
1. Measure the utility AC voltage to
the inverter terminal.
2. Check country & Grid setting
3. Check the detection circuit inside
the inverter
1. Check the utility voltage on the
inverter terminal
2. Check country & Grid setting
3. Check the detection circuit inside
the inverter
1. Check the utility frequency on the
inverter terminal
2. Check country setting
3. Check the detection circuit inside
the inverter
1. Check the utility frequency on the
inverter terminal
2. Check country & Grid setting
3. Check the detection circuit inside
the inverter
46
Action

Advertisement

Table of Contents
loading

Table of Contents