Symptom: White Mist Comes Out Of A Unit (Indoor Unit, Outdoor Unit); Symptom: The Units Can Give Off Odours; Symptom: The Outdoor Fan Rotates While The Air Conditioner Is Not In Operation; Symptom: Airflow Rate Setting Does Not Resume When Comfort Airflow Is Deactivated By Onecta App - Daikin FTXJ20A2V1BW User Reference Manual

Hide thumbs Also See for FTXJ20A2V1BW:
Table of Contents

Advertisement

8
|
Troubleshooting

8.3.8 Symptom: White mist comes out of a unit (Indoor unit, outdoor unit)

8.3.9 Symptom: The units can give off odours

8.3.10 Symptom: The outdoor fan rotates while the air conditioner is not in operation

8.3.11 Symptom: Airflow rate setting does NOT resume when Comfort airflow is deactivated by
ONECTA app
8.3.12 Symptom: The vertical automatic swing operation does NOT resume after the Comfort
airflow operation is deactivated
8.3.13 Symptom: Some operation icons are not visible on the wireless remote control, or some
functions cannot be activated in the ONECTA app

8.3.14 Symptom: In ONECTA app, powerful operation is NOT indicated as active

User reference guide
66
When the system is changed over to heating operation after defrost operation.
Moisture generated by defrost becomes steam and is exhausted.
The unit can absorb the smell of rooms, furniture, cigarettes, etc., and then emit it
again.
After operation has stopped. The outdoor fan continues to rotate for another
30 seconds for system protection.
While the air conditioner is not in operation. When the outdoor temperature is
very high, the outdoor fan starts to rotate for system protection.
If Comfort airflow operation is deactivated by ONECTA app, the airflow rate does
NOT return to previous airflow rate setting, and indoor unit operates in automatic
airflow rate.
Even if the Vertical automatic swing was active before Comfort airflow operation
was deactivated the Vertical automatic swing will NOT resume.
Some combinations of features are not permitted (example: Fan only mode and
Outdoor unit quiet operation). This features may display at the ONECTA app, but
function CANNOT be activated.
When the powerful operation is activated while indoor unit is OFF, the powerful
operation may not be displayed as active for 2  minutes until the cloud data are
updated.
FTXJ-A(W)(S)(B)
Daikin room air conditioner
4P518786-9H – 2021.12