Table of Contents

Advertisement

DAIKIN ROOM AIR CONDITIONER

OPERATION MANUAL

MODELS
FTXJ25TVMAW
FTXJ35TVMAW
FTXJ50TVMAW
FTXJ60TVMAW
FTXJ25TVMAK
FTXJ35TVMAK
FTXJ50TVMAK
FTXJ60TVMAK
Enjoy year-round comfort.
Enjoy year-round comfort.
Enjoy year-round comfort.
Enjoy year-round comfort.
Enjoy year-round comfort.

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FTXJ25TVMAW

  • Page 1: Operation Manual

    DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL Enjoy year-round comfort. Enjoy year-round comfort. Enjoy year-round comfort. Enjoy year-round comfort. Enjoy year-round comfort. MODELS FTXJ25TVMAW FTXJ35TVMAW FTXJ50TVMAW FTXJ60TVMAW FTXJ25TVMAK FTXJ35TVMAK FTXJ50TVMAK FTXJ60TVMAK...
  • Page 2: Table Of Contents

    4-7-1 Precautions when using the wireless adapter....14 be serious depending on the circumstances. 4-7-2 To install the Daikin Mobile Controller application ..14 4-7-3 To set the wireless connection ........14 Never attempt. 5. Energy saving and optimum operation ......16 6.
  • Page 3 WARNING CAUTION • Do not use means to accelerate the defrosting process • Do not use the air conditioner for purposes other or to clean, other than those recommended by the than those for which it is intended. Do not use the air manufacturer.
  • Page 4: About The System

    o Louvres (vertical blades) CAUTION p Flaps (horizontal blades) q Backside of the front panel • Do not place objects in direct proximity of the outdoor r Fixing tab unit and do not let leaves and other debris accumulate s Support around the unit.
  • Page 5: Components: Remote Controller

    2-2-1 Components: Remote controller Operation mode = Drying Operation mode = Heating Operation mode = Cooling Operation mode = Fan only Powerful operation is active Econo operation is active Outdoor unit quiet operation is active The indoor unit receives a signal from the remote controller Current temperature setting Menu (push 2sec)
  • Page 6: Before Operation

    1. Aim the signal transmitter at the signal receiver on the 1. Slide the front cover to take it off. indoor unit (maximum distance for communication is 7 m). 2. Insert 2 dry batteries AAA.LR03 (alkaline). 3. Replace the front cover. Result: When the indoor unit receives a signal from the remote controller, you will hear a sound: Sound...
  • Page 7: Brightness Of The Indoor Unit Display

    3. Press Result: blinks. 4. Press to set the correct time. 5. Press 3. Press to select the menu. Result: blinks. Result: Setting is complete. blinks. 3-4 Brightness of the indoor unit display Adjust the brightness of the indoor unit display as desired, or turn OFF the display.
  • Page 8: When To Use Which Feature

    4-2 When to use which feature Setting Description You can use the following table to determine which features to use: The system cools down or heats up Automatic a room to the temperature setpoint. It Feature Tasks automatically switches between cooling Basic features and heating if necessary.
  • Page 9: Airflow Rate

    To adjust vertical airflow direction 4. Press to stop operation. 1. Press Result: disappears from the LCD. The operation lamp goes off. Result: appears on the LCD. The flaps (horizontal blades) will begin to swing. 4-3-2 Airflow rate 2. To use fixed position, press when the flaps reach 1.
  • Page 10 Intelligent eye operation In heating The airflow direction will change to spread the air along the floor. The system detects movement in the room and automatically The unit detects the room and floor temperature and adjusts the airflow direction and temperature in order to avoid automatically selects 1 of the 3 airflow directions.
  • Page 11: Powerful Operation

    Outdoor unit quiet operation 4-3-5 Powerful operation This operation quickly maximises the cooling/heating effect in Use Outdoor unit quiet operation when you want to decrease any operation mode. You can get the maximum capacity. the noise level of the outdoor unit. Example: At night. INFORMATION INFORMATION •...
  • Page 12: To Start/Stop Flash Streamer Operation

    4-4-1 To start/stop Flash streamer operation 4. To stop operation, press 1. Press Result: disappear from the LCD and the timer Result: is displayed on the LCD and the air in the room lamp goes off. and the day of the week are displayed on the LCD. is cleaned.
  • Page 13: Weekly Timer Operation

    4-6 Weekly timer operation 4-6-1 To set Weekly timer operation 1. Press With this operation, you can save up to 4 timer settings for each Result: The day of the week and the reservation number day of the week. of the current day are displayed. Example: Create a different setting from Monday to Friday and a different setting for weekends.
  • Page 14: To Copy Reservations

    4-6-3 To confirm reservations 8. Press to select the desired temperature. You can confirm if all reservations are set to your needs. Note: The set temperature for the weekly timer is displayed only when setting the weekly timer mode. 1. Press Result: The day of the week and the reservation number of the current day are displayed.
  • Page 15: Wireless Lan Connection

    • Microwave oven. It may affect wireless LAN communications. 1. Hold for at least 5 seconds in the default screen. 4-7-2 To install the Daikin Mobile Controller application Result: The confirmation display (menu ) appears. 1. Open: 2. Press repeatedly until the WPS setting display •...
  • Page 16 To reset the connection setting to the factory default 3. Press to confirm the selection. Result: is blinking. Reset the connection setting to the factory default in case you want to: 4. Press the WPS button on your communication device (e.g.router) within approximately 1 minute.
  • Page 17: Energy Saving And Optimum Operation

    5. Energy saving and optimum operation • Adjust the room temperature properly for a comfortable environment. Avoid excessive heating or cooling. Notice that it may take some time for the room temperature to reach the set temperature. Consider using the timer setting options. INFORMATION •...
  • Page 18: To Clean The Indoor Unit And Remote Controller

    6-3 To clean the front panel NOTICE Maintenance MUST be done by an authorized installer or service agent. We recommend performing maintenance at least once a year. However, applicable legislation might require shorter maintenance intervals. 1. Clean the front panel with a soft cloth. If it is difficult to remove stains, use water or a neutral detergent.
  • Page 19: To Clean The Air Filters

    6-6 To clean the air fi lters 6-7 To clean the titanium apatite deodorising fi lter 1. Hold the tab at the centre of each air fi lter and pull up a little. INFORMATION 2. Pull out the air fi lters. Clean the filter with water every 6 months.
  • Page 20: To Remove The Front Panel

    6-9 To remove the front panel 6-10 Take following items into account before a long idle period Operate the unit several hours in fan only mode to dry the inside INFORMATION of the unit. Remove the front panel only in case it MUST be replaced. 1.
  • Page 21 Malfunction Measure Malfunction Measure • Check if there is no power failure. If the system does The system • To prevent the release of cold air, NOT operate at all. Wait until power is restored. If a operates, but air does not come out directly after power failure occurs during operation, heating is insufficient operation is started.
  • Page 22: Symptoms That Are Not System Malfunctions

    7-1-9 Symptom: White mist comes out of a unit Malfunction Measure (Indoor unit, outdoor unit) The OPERATION Check if the display brightness setting is ■In heating operation lamp is off, but the set to “OFF.” Refer to “3-4 Brightness of unit is operating the indoor unit display”...
  • Page 23: Troubleshooting For Wireless Connection Adapter

    7-3 Troubleshooting for wireless connection adapter System Error code Description The following table provides a brief description of how to deal Normal with some problems. If none of the following solutions fix the problem, go to http://www.daikinthai.com/dmobile/index.html/ Refrigerant shortage for more information and FAQ. Overvoltage detection Signal transmission error (between indoor and Problem...
  • Page 24 The two-dimensional bar code is a manufacturing code. 3P524249-1 M17B306 (1806) HT...

Table of Contents