Advertisement

Air Conditioning

Technical Data

Wall mounted unit
EEDEN16
FTXJ-MS, FTXJ-MW

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FTXJ-MS

  • Page 1: Technical Data

    Air Conditioning Technical Data Wall mounted unit EEDEN16 FTXJ-MS, FTXJ-MW...
  • Page 3: Table Of Contents

    ......... . 12 • Split - Sky Air • FTXJ-MS, FTXJ-MW...
  • Page 4: Features

    • Whisper quiet in operation: the operating of the unit can hardly be heard. The sound pressure level goes down to 19dBA! • Daikin Emura has been awarded many times, thanks to its excellent design Practically Silver allergen Econo mode...
  • Page 5: Specifications

    46/40/35/ Silent operation Heating High/Nom./Low/ 40/34/28/ 41/34/28/ 45/37/29/ 47/41/35/ 40/34/28/ 41/34/28/ 45/37/29/ 47/41/35/ Silent operation Control systems Infrared remote control ARC466A9 Temperature control Microcomputer control Air direction control Right, Left, Horizontal, Downward • Split - Sky Air • FTXJ-MS, FTXJ-MW...
  • Page 6: Electrical Specifications

    Nominal running Cooling 0.12 0.16 0.12 0.16 current (RLA) - 50Hz Heating 0.15 0.16 0.21 0.22 0.15 0.16 0.21 0.22 Notes SL: The silent fan level of the air flow rate setting • Split - Sky Air • FTXJ-MS, FTXJ-MW...
  • Page 7: Options

    Schedule timer DST301BA51 Titanium apatite photocatalytic air-purifying filter with frame KAF970A46 ① Anti-theft protection for remote control KKF910AA4 Notes Legend R32 models ① Three-dimensional knitted fabric (42x255mm) + activated charcoal net 3D095173C • Split - Sky Air • FTXJ-MS, FTXJ-MW...
  • Page 8: Dimensional Drawings

    • Indoor Unit • FTXJ-MS, FTXJ-MW Dimensional drawings 4 - 1 Dimensional Drawings • Split - Sky Air • FTXJ-MS, FTXJ-MW...
  • Page 9: Centre Of Gravity

    • Indoor Unit • FTXJ-MS, FTXJ-MW Centre of gravity 5 - 1 Centre of Gravity • Split - Sky Air • FTXJ-MS, FTXJ-MW...
  • Page 10: Piping Diagrams

    • Indoor Unit • FTXJ-MS, FTXJ-MW Piping diagrams 6 - 1 Piping Diagrams 6.4CuT 6.4CuT 9.5CuT 9.5CuT • Split - Sky Air • FTXJ-MS, FTXJ-MW...
  • Page 11 • Indoor Unit • FTXJ-MS, FTXJ-MW Piping diagrams 6 - 1 Piping Diagrams 6.4CuT 6.4CuT 12.7CuT 9.5CuT • Split - Sky Air • FTXJ-MS, FTXJ-MW...
  • Page 12: Wiring Diagrams

    • Indoor Unit • FTXJ-MS, FTXJ-MW Wiring diagrams 7 - 1 Wiring Diagrams - Single Phase • Split - Sky Air • FTXJ-MS, FTXJ-MW...
  • Page 13: Sound Data

    Operating conditions: power source 220-240 V/220 V 50/60 Hz; JIS standard Background noise already taken into account. Operating noise varies depending on operation and ambient conditions. The operation noise measuring method is in accordance with JISC9612. Measuring location: anechoic chamber 3D092361A • Split - Sky Air • FTXJ-MS, FTXJ-MW...
  • Page 14 Operating conditions: power source 220-240 V/220 V 50/60 Hz; JIS standard Background noise already taken into account. Operating noise varies depending on operation and ambient conditions. The operation noise measuring method is in accordance with JISC9612. 3D092360A Measuring location: anechoic chamber • Split - Sky Air • FTXJ-MS, FTXJ-MW...
  • Page 16 All content is copy- righted by Daikin Europe N.V. Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende...

This manual is also suitable for:

Ftxj-mw

Table of Contents