Internal Memory; Electrical Characteristics - Epson EU-m30 Series Developer's Manual

Table of Contents

Advertisement

1.9

Internal Memory

(1)
Receive buffer
4 KB or 45 bytes (Select using software settings)
(2)
Downloaded character area
12 KB (Shared with the downloaded bit image area)
(3)
Macro area
2 KB
(4)
NV graphics area
384 KB
(5)
Downloaded graphics area
208 KB
(6)
NV user memory area
1 KB
1.10

Electrical Characteristics

(1)
Supply voltage
+24 VDC ± 7%
*Safety Information
Be sure to use a safety-standards-applied power source that meets the following specifications.
Rated output: 24V/2.1A - 10.0A, Maximum output: 240VA or less
(2)
DC current consumption (at 24 VDC, 25°C {77°F}, normal print density)
Operating: See Table 1.10.1 to 1.10.2.
Standby: Average current 0.1 A
10