that time.
Also, if the time from the completion of a print job (end of operation) to the start of the next print job is less
than 640 ms, the next print job will start without flashing.
For details, see 3.5.2 Software setting.
*5
A Near-End Error (orange) LED and Printing Completed (blue/attention) LED will not flash at the same
time.
3.5

Printer Setting

3.5.1

DIP switch settings

This printer is not equipped with DIP switches.
3.5.2

Software setting

(1)
Memory switches
Can be changed using one of the following methods.
(a) User setup commands: GS ( E
Step 1:
Moves to the user setting mode with GS ( E <Function 1>
Step 2:
Change settings with GS ( E <Function 3>.
Step 3:
End the user setting mode with GS ( E <Function 2>.
For details, see "ESC/POS Command Reference" (www.epson-biz.com/pos/reference/).
(b) Software setting mode (except some functions)
For details, see 3.8.3 Software setting mode.
(c) EU-m30 Utility
Msw
1-1
(Reserved)
1-2
Receive buffer capacity
1-3
Condition for BUSY
1-4
Data processing with reception error Replace with "?"
1-5
Automatic line feed
1-6
(Reserved)
1-7
Pin 6: Reset signal selection
1-8
(Reserved)
1 segment: 160 ms
ERROR LED
Flashing LED
 
640 ms
Table 3.5.1 Memory Switch 1 (Msw1)
Function
 Elapsed time 
 
640 ms
Setting value
48 (OFF)
-
-
4 KB
45 bytes
Receive buffer full
Receive buffer full
and offline
Ignored
Always disabled
Always enabled
-
-
Not used
Used
-
-
Factory
setting
49 (ON)
48 (OFF)
48 (OFF)
48 (OFF)
48 (OFF)
48 (OFF)
48 (OFF)
48 (OFF)
48 (OFF)