NOTICE TO INSTALLER: Instructions must remain with installation.
Product information presented
here re fl
e
s t c
o c
d n
o i t i
s n
a
t t
m i
e
of publication. Consult factory
e r
a g
i d r
g n
d
c s i
e r
a p
c n
s e i
r o
n i
o c
s n
t s i
n e
e i c
. s
Register your
Zoeller Pump Company
Product on our website:
http://reg.zoellerpumps.com/
1. Inspect all materials. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using. DO NOT remove the
test plugs from the pump.
2. Carefully read all the literature provided to familiarize yourself with
future reference.
SEE BELOW FOR LIST OF WARNINGS
1. To reduce the risk of electrical shock, a properly grounded receptacle or
control box must be installed in accordance with the governing codes. Never
remove ground pin from plug.
2. Make certain that the ground fault interrupter protected receptacle or control
box is within the reach of the pump's power supply cord. DO NOT USE AN
EXTENSION CORD. Extension cords that are too long or too light do not
deliver
voltage to the pump motor, and they could present a safety
hazard if the insulation were to become damaged or the connection end were
to fall into a damp or wet area.
3. Make sure the pump's electrical supply circuit is equipped with fuses or circuit
breakers of proper capacity. A separate branch circuit is recommended, sized
according to the governing electrical codes for the current shown on the pump
name plate.
4. Testing for ground. As a safety measure, each electrical outlet should be
checked for ground using an Underwriters Laboratory Listed circuit analyzer
which will indicate if the power, neutral and ground wires are correctly connected
to your outlet. If they are not, call a
5. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS
POWER SOURCE BEFORE HANDLING. If pump is wired direct, de-energize
the circuit at the control box. DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE THE GROUND PIN. Wear insulated protective shoes and do not
stand in water. Certain plug types may include a 3-prong ground plug to help
protect against electrical shock. A properly grounded 3-prong receptacle or
control box must be installed in accordance with governing codes.
6. Installation and servicing of the pump's electrical circuits and hardware should
only be performed by a
7. Installation and maintenance of this appliance is not intended for persons
(including children) with reduced physical, sensory or mental capabilities, or
lack of experience or knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their
safety.
8. Risk of electrical shock. Do not remove power supply cord and strain relief
or connect conduit directly to the pump. If the supply cable is damaged, it
must be replaced by an authorized Zoeller Representative.
9. Pump contains oil which becomes pressurized and hot when operating. Allow
2-1/2 hours after disconnecting before attempting service.
1
. 0
u P
m
p
is not intended for potable water due to possible contamination by oil
contained in the pump.
11. Risk of electrical shock. These pumps have not been investigated for use
in swimming pools and marine areas.
QWIK JON
®
PREMIER 201 SYSTEM
INSTALLATION INSTRUCTIONS
PREINSTALLATION CHECKLIST
licensed electrician.
licensed electrician.
© Copyright 2022 Zoeller
details regarding installation and use. These materials should be retained for
SAFETY INSTRUCTIONS
TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR
PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY
INSTRUCTIONS IN THIS MANUAL AND ON THE PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION AND
OPERATION OF THIS UNIT AND MUST BE KEPT WITH THE PUMP.
This is a SAFETY ALERT SYMBOL.
Symbol on the pump or in the manual, look for one of the
following signal words and be alert to the potential for
personal injury or property damage.
Warns of hazards that CAN cause serious personal injury,
death or major property damage.
Warns of hazards that CAN cause personal injury or
CAUTION
property damage.
Warns of electrical shock hazards that can cause serious
personal injury, death or major property damage.
Identifies any terminal which is intended for connection to
an external conductor for protection against electrical
shock in case of a fault, or the terminal of a protective
earth (ground) electrode.
Read operator's manual.
THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS PRIOR
TO PERFORMING ANY WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
REFER TO WARRANTY ON PAGE 2.
®
Co. All rights reserved.
- 1 -
ZT0502_Eb
Supersedes
50 Hz
Visit our website:
www.zoellerpumps.com
0422
1221

Advertisement

Table of Contents
loading

Summary of Contents for Zoeller QWIK JON PREMIER 201

  • Page 1 8. Risk of electrical shock. Do not remove power supply cord and strain relief or connect conduit directly to the pump. If the supply cable is damaged, it must be replaced by an authorized Zoeller Representative. 9. Pump contains oil which becomes pressurized and hot when operating. Allow 2-1/2 hours after disconnecting before attempting service.
  • Page 2: Limited Warranty

    DO NOT recommend. Contact dealer if unit appears to be damaged. 9. DO inspect and test system for proper operations at least every 3 months. ® © Copyright 2022 Zoeller Co. All rights reserved. - 2 -...
  • Page 3: Service Parts

    Tank Repair Kit 085162 Side Inlet Valve Repair Kit 084672 Bellow Repair Kit 084840 Pump Repair Kit 085185 Discharge Elbow Pipe Repair Kit 085164 Vent Valve Repair Kit 084858 © Copyright 2022 Zoeller ® Co. All rights reserved. - 3 -...
  • Page 4: Troubleshooting

    Vertical lift too high. Department. If the above checklist does not solve the problem, consult the Zoeller Product Support Department by sales@zoeller.com.tw Do not attempt to service or otherwise disassemble pump. Care of finish: soap and water is all that is recommended for cleaning the outside of the tank. Other cleaning products may cause discoloration and scratching.
  • Page 5: Location Selection

    Do not use wooden shims to level the pump unit. Ensure that nails, screws or other sharp objects do not puncture the pump unit. Level the pump unit to within (1/8”) using hydraulic cement or similar material. © Copyright 2022 Zoeller ® Co. All rights reserved. - 5 -...
  • Page 6 Connect the rear discharge toilet to the front inlet of the Qwik Jon Premier via hose clamps. Ensure the connec�ons are ® according to local, regional, and state codes. *These drawings are for reference only. Exact components may differ by region. © Copyright 2022 Zoeller Co. All rights reserved. ® - 6 -...
  • Page 7 Clean, prime and solvent weld the discharge piping and pump unit Cut cleanly and remove burrs and rough edges to avoid discharge the potential for clogging. Ø89 mm (Ø3-1/2”) 384 mm (15-1/8”) 178 mm (7”) 38 mm (1-1/2”) © Copyright 2022 Zoeller Co. All rights reserved. ® - 7 -...
  • Page 8 Exact components may differ by region. Connect the discharge pipe to the top of the Qwik Jon Premier. ® *These drawings are for reference only. Exact components may differ by region. © Copyright 2022 Zoeller Co. All rights reserved. ® - 8 -...
  • Page 9 STEP 5 POWER Plug the power cord into a wall socket to provide power to the unit. *These drawings are for reference only. Exact components may differ by region. © Copyright 2022 Zoeller Co. All rights reserved. ® - 9 -...
  • Page 10: Maintenance

    Exact components may differ by region. Remove the discharge pipe from the top of the Qwik Jon® Premier. *These drawings are for reference only. Exact components may differ by region. © Copyright 2022 Zoeller Co. All rights reserved. ® - 10 -...
  • Page 11 *These drawings are for reference only. Exact components may differ by region. Take the lid off the Qwik Jon ® Premier. *These drawings are for reference only. Exact components may differ by region. © Copyright 2022 Zoeller Co. All rights reserved. ® - 11 -...
  • Page 12 The discharge elbow pipe can be disconnected from the volute of the pump to be cleared of debris. *These drawings are for reference only. Exact components may differ by region. © Copyright 2022 Zoeller Co. All rights reserved. ® - 12 -...
  • Page 13 TOTAL DYNAMIC HEAD / FLOW MODEL 220V / 50Hz Feet Meters Liters m / hr 10.2 170.3 147.6 124.9 94.6 49.2 Shut-off Head 9m (29.5ft) m /hr FLOW 084975 © Copyright 2022 Zoeller Co. All rights reserved. ® - 13 -...
  • Page 14 DECLARATION OF CONFORMITY We, Zoeller, declare under our sole responsibility that the models xxx to which this declara�on relates, are in conformity with the Council Direc�ves on the approxima�on of the laws of the EC Member States rela�ng to: -- Electromagne�c Compa�bility (2014/30/EU)

Table of Contents