CONDITION
A. PUMP W ILL NOT
START OR RUN.
B. PUMP W ILL NOT
SHUT OFF OR RUNS
TOO LONG BEFORE
W ATER IS PUMPED.
C. PUMP OPERATES
BUT DELIVERS LITTLE
OR NO W ATER
If the above checklist does not solve the problem, consult the Zoeller Product Support Department by sales@zoeller.com.tw Do not attempt to service or otherwise
disassemble pump.
Care of finish: soap and water is all that is recommended for cleaning the outside of the tank. Other cleaning products may cause discoloration and scratching.
384 mm
(15-1/8")

TROUBLESHOOTING

POSSIBLE CAUSE
Low voltage, open circuit, failed capacitor.
Impeller bound and cutter bound.
Motor or wiring shorted.
Debris on float switch.
Debris under float.
Faulty float switch
Pump is air locked.
Waste material has accumulaled blocking flow
of material to pump intake.
Debris around intake.
Blockage in discharge pipe.
Low or incorrect voltage.
Damaged Impeller.
Incorrect float adjustment.
Pump is air locked.
Vertical lift too high.
DIMENSIONS
488 mm
(19-1/4")
© Copyright 2022 Zoeller
Have a qualified electrician check the circuit.
Contact a Zoeller Authorized Service and Warrenty Center.
Remove debris.
Remove debris from around float.
Contact a Zoeller Authorized Service and Warrenty Center.
Make sure vent hole in discharge pipe is clear.
Hold flush handle down on toilet for 15 seconds. If unit will
not clear, unplug and wait for 30 minutes. Plug unit back in
and repeat. If unit still will not turn off, it will need to be
opened and the debris removed.
Clean area around intake.
Remove pipe and flush out debris.
Have a qualified electrician check house wiring.
Contact a Zoeller Authorized Service and Warrenty Center.
Contact Product Support Department.
Make sure vent hole in discharge pipe is clear.
Change dicharge piping or contact Product Support
Department.
188 mm
(7-3/8")
Ø89 mm
(Ø3-1/2")
178 mm
(7")
38 mm
(1-1/2")
®
Co. All rights reserved.
- 4 -
REMEDY
for Installations in markets where a
carbon filter vent is allowed, please
replace the carbon filter periodically,
P/N 081887.
233 mm
(9-1/8")
121 mm
(4-3/4")

Advertisement

Table of Contents
loading

Table of Contents