OPTION JUMPERS

10
Jumpers 1, 2 and 3 set the mode to Fast (40msec response) or Slow (110msec response),
Spread Spectrum, and external sync.
Table 2 — Jumpers 1, 2, 3: Fast, Slow, Spread Spectrum Modes
Description
JMP 1
Fast Mode & Spread Spectrum
B
Fast Mode Only
None
Slow Mode Only
None
Slow Mode & External Sync
A
Jumpers 4 and 5 set Normal or Toggle mode, and max on-duration time (delay to recal after
prolonged detection).
Table 3 — Jumpers 4, 5: Toggle, Max On-Duration Settings
Output
Max On-
Mode
Duration*
Normal
10 secs
Normal
60 secs
Normal
Infinite
Toggle mode
10 secs
* Max On-Duration is the amount of continuous detection time before the key auto-recalibrates.
Factory
JMP 2
JMP 3
Default
Yes
B
None
B
None
A
None
A
Factory
JMP 4
JMP 5
Default
B
A
A
B
B
B
A
A