300010003
The node has failed to reboot within the specified time period.
One or more nodes are offline due to one of the following conditions:
● A node was intentionally shut down for maintenance.
● A node lacks internal network connectivity. Internal connectivity is how a node communicates with other nodes on the
cluster.
● A node cannot join the group.
Administrator action
If the Cluster Status page in the OneFS web administration interface indicates that a node is down, complete the following
steps.
1. Determine whether the node is turned on. Visually inspect the node to verify that the power light is on.
2. If the node is turned off, attempt to turn the node on.
● If the node turns on, view the Cluster Status page to determine whether the node has rejoined the cluster. If the node
does not rejoin the cluster, proceed to step 3.
● If the node rejoins the cluster, and the cluster is operational, the event will cancel.
● If the node does not turn on, make sure that any circuit breakers in the power path are closed and that the power outlets
for the node are active. If the node is not receiving power, resolve the power supply issue. If the node is receiving power,
contact Technical Support.
3. If the node is on but did not rejoin the cluster, attempt to establish remote access through a secure shell (SSH) session. If
the SSH session fails, attempt to establish remote access through the serial console.
4. If neither the SSH session nor the serial console is responsive, press CTRL+T in the SSH session or in the serial console.
● If pressing CTRL+T produces output, record the output, and then contact Technical Support for failure analysis.
● If the node is unresponsive, turn the power off and then on again.
300020001
A read-only transition failed on the node.
Description
A read-only transition occurs when a node or drive changes from a writeable state to a read-only state, such as during a node
shutdown. This event is generated if this transition fails for any reason.
Administrator action
If the node or drive changes to a read-only state, and this event is temporary, no action is required.
If the event persists, gather logs, and then contact Technical Support for additional troubleshooting. For instructions on how to
gather cluster logs, see
Gathering cluster
300020002
Validation of a node journal backup failed.
Administrator action
This message is informational. No action is required.