Dell PowerScale OneFS Reference Manual page 51

Table of Contents

Advertisement

100010058
A node pool does not meet the minimum storage space requirement for large files: {node_pool_name} (id={node_pool_id})
Description
The event indicates that the Large File feature was previously enabled, but the node pool does not meet the minimum storage
space capacity requirement.
Administrator action
If the event persists, gather logs, and then contact Technical Support for additional troubleshooting. For instructions on how to
gather cluster logs, see
Gathering cluster
100010059
Node pool {nodepool_name} (node pool ID: {nodepool_id}) is at, or over capacity for large files.
Description
The event indicates that the Large File feature is enabled and a node pool has passed the space in-use in threshold. System
performance can be affected.
Administrator action
If the event persists, gather logs, and then contact Technical Support for additional troubleshooting. For instructions on how to
gather cluster logs, see
Gathering cluster
100010060
Error detected in PCI drive: Location {location}, Type {media_type}, LNUM {disk}: {aer}.
Description
PCI advanced error reporting is reporting an NVMe drive error.
Administrator action
Replace the NVMe drive.
100010061
Error detected in NVMe drive: Location {location}, Type {media_type}, LNUM {disk}: {detail}.
Description
NVMe error log has reported a new error. The event checks the error log page of an NVMe drive. The error log page contains
the last command that failed IIRC.
logs.