downlink bandwidth = total bandwidth between leaf and all Isilon nodes.
This indicates the uplink bandwidth does not equal the downlink bandwidth, causing an imbalance in the fabric and subsequent
bottleneck.
Administrator action
Correct wiring to ensure uplink bandwidth is equal to downlink fabric for a single fabric (int-a and/or int-b as specified).
200020024
Fabric bandwidth incongruence.
Description
In a leaf-spine configuration, verify that uplink bandwidth is equal on int-a and int-b fabric.
This indiacates that the primary and failover bandwidths differ. When a failover occurs the performance of the cluster may be
impacted.
Administrator action
Correct wiring to ensure primary and secondary fabric are in the same configuration so their bandwidths are identical.
200020025
Back-end network non-connectivity.
Description
Back-end network non-connectivity detected: No connectivity between nodes 215 and 252 on the Int-a network.
Administrator action
Obtain a full list of nodes with no connectivity between them, by running the isi_check_be command. Restore connectivity.
200020026
A network interface card is unhealthy.
Description
A network interface card is unhealthy and may require maintenance or replacement depending on the card.
Administrator action
Determine which network interface card is unhealthy. The interface name is specified in the event. Some errors are self-
recoverable, but other errors might require replacement of the network card.
64