Modify alerts by event type id
You can suppress or un-suppress one or more event type ID depending on its current state.
1. Click Cluster Management > Events and Alerts > Alert Management.
2. In the Actions column of the event type ID you want to modify, click Suppress or Un-suppress.
You can perform an action on multiple event type IDs by selecting the check box next to the event type ID of the alerts you
want to change, then selecting an action from the Select a bulk action list.
View alerting rules
You can view a list of all the alerting rules.
1. Click Cluster Management > Events and Alerts > Alert Management.
2. In the CELOG alerting area, click the Alerting rule tab.
You can view the list of alerting rules.
Create an alerting rule
You can create an alerting rule.
1. Click Cluster Management > Events and Alerts > Alert Management.
2. In the CELOG alerting area, click the Alerting rule tab.
3. Click Create alert rule.
The Create alert rule window appears.
4. Enter the following details:
● Rule name: Enter a name for the new alerting rule.
● Rule condition: Select a condition (New, New Events, Ongoing, Severity Increase, Severity decrease, Resolved) from the
drop-down list.
● Send an alert only if the event lasts longer than: Enter the numerical value in the text box and select the unit of time
from the drop-down list.
● Applies to: Select the check box next to the relevant alert category.
● Add event group ID: Click Add event group ID to add an event group.
● Select alert channel for this rule: Select the check box next to the relevant channel name.
5. Click Create rule.
Modify an alerting rule
You can modify an existing alerting rule.
1. Click Cluster Management > Events and Alerts > Alert Management.
2. In the CELOG alerting area, click the Alerting rule tab.
3. In the Actions column of the alerting rule you want to modify, click Edit rule.
The Edit alert rule window appears.
4. Modify the following details:
● Rule name: You cannot modify the name for an existing alerting rule.
● Rule condition: Select a condition (New, New Events, Ongoing, Severity Increase, Severity decrease, Resolved) from the
drop-down list.
● Send an alert only if the event lasts longer than: Modify the numerical value in the text box and select the unit of time
from the drop-down list.
● Applies to: Select the check box next to the relevant alert category.
● Add event group ID: Click Add event group ID to add a new event group.
● Select alert channel for this rule: Select the check box next to the relevant channel name.
5. Click Save Changes.
20
Introduction to system events