Dell PowerScale OneFS Reference Manual page 108

Table of Contents

Advertisement

● Isilon Dynamic sector recovery (DSR) failures - Event ID: 800010005,
Gather logs, and then contact Technical Support for additional troubleshooting. For instructions on how to gather cluster logs,
see
Gathering cluster
logs.
800010004
The cluster has encountered a file system error.
Administrator action
Gather logs, and then contact Technical Support for additional troubleshooting. For instructions on how to gather cluster logs,
see
Gathering cluster
logs.
800010005
The Dynamic Sector Repair (DSR) process failed to resolve a data verification error.
Description
The system has failed to resolve this issue automatically. Manual intervention is required.
Administrator action
Gather logs, and then contact Technical Support for additional troubleshooting. For instructions on how to gather cluster logs,
see
Gathering cluster
logs.
800010006
A node has reported that the number of available file descriptors is approaching the maximum limit.
Administrator action
1. Identify a list of the process types with the largest number of file descriptors by running the following command from the
OneFS command-line interface:
fstat|awk '{ print $2 }'|sort|uniq -c|sort -rn|head
2. Contact Dell EMC PowerScale Technical Support and provide the output from the command.
800010007
An Isilon Data Integrity (IDI) network checksum error was detected.
Description
One or more nodes appear to have faulty back-end networking hardware within the node, or a faulty motherboard.
108
Software events
article 000041433