Dell PowerScale OneFS Reference Manual page 199

Table of Contents

Advertisement

900180031
NVDIMM is in the wrong DIMM slot.
Description
NVDIMM was replaced in the wrong DIMM slot.
Administrator action
See the OEM manual for proper DIMM replacement procedure, and replace the NVDIMM int the correct slot.
900180032
NVDIMM subsystem health is not being monitored. The node transitions to read-only mode until the issue has been resolved.
Description
Dell PowerTools are not responding to service requests.
Administrator action
To determine the problem, run the isi_hwmon -b IDRACServices command.
910100001
A fan in the node might have failed.
Description
If the fan speed temporarily falls out of optimal range for less than a minute or so and the event does not repeat, this event
might be a false alarm.
Administrator action
Follow the instructions in Event notification: Fan speed out of spec,
article 000083406
to determine if this event is a false
alarm.
If this event is not a false alarm, contact Technical Support.
910100002
A voltage component is out of specification.
Administrator action
Gather logs, and then contact Technical Support for additional troubleshooting. For instructions on how to gather cluster logs,
see
Gathering cluster
logs.
Hardware events
199

Advertisement

Table of Contents
loading

Table of Contents