Administrator action
Gather logs, and then contact Technical Support for additional troubleshooting. For instructions on how to gather cluster logs,
see
Gathering cluster
logs.
900160022
The Baseboard Management Controller (BMC) in a peer node is not responding.
Description
The BMC monitors hardware components such as batteries and power supplies. To make sure that these hardware components
continue to be monitored, the peer node must be serviced immediately. Troubleshooting is required to determine if a hardware
component must be replaced.
The event message provides you with the chassis and node slot of the affected node.
Administrator action
Gather logs, and then contact Technical Support for additional troubleshooting. For instructions on how to gather cluster logs,
see
Gathering cluster
logs.
900160023
A node journal is in an unprotected state.
Description
When a node is disconnected from its peer node, the node journals are not mirrored and data is at risk. The event message
provides you with the chassis and node slot where the disconnected node is located.
Administrator action
1. Confirm that both nodes are cabled correctly and powered up.
2. If the issue persists, contact Dell EMC PowerScale Technical Support to determine if a replacement node is required.
Gather logs, and then contact Technical Support for additional troubleshooting. For instructions on how to gather cluster
logs, see
Gathering cluster
900160024
A delayed reboot event occurred and the identified node was set to read-only to protect the journal.
Description
When node firmware identifies certain risk conditions, the firmware places the node in a delayed reboot state.
If the condition is cleared quickly, the delayed reboot state will be cleared and the node will return to read-write mode. If the
condition persists, the node will reset.
logs.