3.
The order of RAID array creation:
To create 2 RAID arrays, start from the disk with a larger slot ID, so as not
to reverse the order after creating 2 RAID arrays in sequence.
(For example, a SAS controller card connects 6 drives, namely drives in Slot 0, 1,
2, 3, 4, and 5. It is planned to create a RAID 1 array with drives in Slot 0 and 1
and a RAID 10 array with drives in Slot 2, 3, 4, and 5. Specifically, select drives
in Slot 2, 3, 4, and 5 to create the RAID 10 array first, and then select drives Slot
0 and 1 to create the RAID 1 array. Thus, Slot 0 and 1 precede Slot 2, 3, 4, and
5.)
2.3
Environmental Parameters of SAS RAID
Controller Cards
This section describes the environmental parameters of SAS RAID controller cards.
The environmental parameters of Inspur SAS RAID controller are shown below.
Table 2-1 Environmental Parameters
Specification
MTBF
Operating Voltage
Operating Temperature
Storage Temperature
Relative Humidity
Form Factor
12 G SAS
> 2,000,000 hours
+12 V ± 8%; 3.3 V ± 8%
0°C - 55°C (32℉ - 131℉)
-45°C - 105°C (-49℉ - 221℉)
5% - 90% (non-condensing)
Low Profile (2.6" × 6.6")