Wassermann Steam Box User Manual

Cleaning cabin for workpieces

Advertisement

Quick Links

Steam Box
Cleaning cabin
for workpieces
USER MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Wassermann Steam Box

  • Page 1 Steam Box Cleaning cabin for workpieces USER MANUAL...
  • Page 2 Dear customer, Thank you for choosing a product from the Wassermann range. Wassermann Dental- Maschinen incorporates the highest standards of quality and the latest technology. In order to enjoy maximum performance and years of trouble-free operation, please read this user manual carefully before you connect this device and start work, and operate the device according to the recommended guidelines.
  • Page 3: Table Of Contents

    Contents 1 Features..........................4 2 Safety Symbols used in this Manual.................4 3 Safety Guidelines......................5 4 Responsibility for Operation or Damage................5 5 Application.........................6 6 Before Starting........................6 6.1 Transport........................6 6.2 Installation........................6 6.3 Storage........................7 7 Installation/ Start-up......................7 7.1 Start-up........................8 8 Operation..........................9 8.1 General Operating Instructions..................9 8.2 Handling of the Unit....................10 9 Troubleshooting......................11 10 Care and Maintenance....................12...
  • Page 4: Features

    Features Compact cleaning cabin for steam cleaning of workpieces • Generous working opening (W= 285 mm, H= 235 mm) • Quick steam extraction through powerful fan with run-on control • Fan control selectable between continuous operation and automatic mode • Automatic fan operation selectable via foot pedal or hand sensor control •...
  • Page 5: Safety Guidelines

    The unit has to be maintained and operated in accordance with this user manual. Wassermann Dental-Maschinen GmbH is not responsible for damage arising from the nonobservance of these instructions.
  • Page 6: Application

    Application The Steam Box is a compact work cabin for cleaning workpieces with steam. It is designed for the cleaning of small parts up to hand-sized parts. A powerful fan, which quickly extracts the steam via a floor filter, and work area illumination with LED light ensure optimum visibility when working.
  • Page 7: Storage

    Storage The unit location is very important when it comes to workplace safety, even if it is only to be set up there for a short period. The room should be dry, well ventilated and vibration- free. An even temperature and wooden supports also help. The unit should not be stored or set up outdoors.
  • Page 8: Start-Up

    Start-up Before first usage of the cleaning cabin, please completely remove all accessories and the packaging material. Before using the cleaning cabin, select the fan operating mode, i.e. whether the fan is always switched on (continuous operation) or only when working (automatic mode). In the automatic version you can choose between hand sensor and foot pedal control.
  • Page 9: Operation

    Operation General Operating Instructions All instructions for using the unit, whether in verbal or written form, are based on our own experience and experimentation and can only be regarded as guidelines. Use heat-resistant gloves or holding tools for the parts to be cleaned. If the unit is not used for a longer period of time, the mains plug should be pulled out.
  • Page 10: Handling Of The Unit

    Handling of the Unit Select the appropriate operating mode of the fan using the selector switch. • Turn on the green main switch. • Hold the workpiece to be cleaned in the work cabin and clean it with a steam gun. •...
  • Page 11: Troubleshooting

    Switch to footswitch or sensor defective Please contact our service Dark workroom LED lighting defective Please contact our service Steam box without Main switch (green) Please contact our service function defective Check fuse / replace if necessary - if fuse of the socket defective...
  • Page 12: Care And Maintenance

    Care and Maintenance 10.1 Cleaning Disconnect the power plug before starting any maintenance work. The identification plate has always to be kept in easily legible condition and has not to be removed. Remove external dirt from time to time with some form of cold cleaner. Use only cold cleaners to avoid damaging the paintwork or removing the lettering.
  • Page 13: Maintenance

    10.2 Maintenance Check the filter inserts for leakage at regular intervals. If the dirt is too heavy, the corresponding filter elements must be replaced in order to ensure optimal steam extraction. Filter elements (4 pieces) - floor filter (work space) To check the filter element - protective filter (fan), you must remove the front of the housing with the steam cabin, as described below.
  • Page 14 (6-pin) and then pull the front of the housing with the steam cabin forward using the grip plates and set it aside. Now you can check the collecting tray (= chassis floor) and the drain hole as well as other filter elements. Then reassemble the steam box accordingly.
  • Page 15: Repairs

    If necessary please contact our service hotline phone. 10.5 Service Hotline 0049 (0)40 730 926 -20/ -24 10.6 Scope of Delivery/ Accessories/ Spare Parts Steam Box (Item no. 174970) Included in delivery: Drain hose, 2 m • Accessories Item no.
  • Page 16: Warranty

    This warranty does not cover damage caused by improper use, external mechanical causes, transport damage or interference with the unit by unauthorized persons. Technical Data Steam Box Item no.: 174970 Voltage* 220–240 V / 50/60 Hz Power consumption 0.8 A...
  • Page 17: Disposing Of The Unit

    Within the European Union units with this symbol should not therefore be disposed of in unsorted domestic waste. For more information regarding proper disposal please apply at your local authoritie. Your Contact at Wassermann Dental-Maschinen You have questions concerning our products or services? Contact us! We guarantee quickest possible handling and we will provide you personally with competent, dedicated help.
  • Page 18: Eu Declaration Of Conformity

    W A S S E R M A N N Product description: xxx for dental Dental-Maschinen GmbH applications Rudorffweg 15-17 21031 Hamburg Germany Model: Steam Box Item no. 174970 Applicable DIN EN 61010-1 standards: DIN EN 61000-6-3 DIN EN 61000-6-1 DIN 45635-1 DIN EN 60335-1 Hiermit wird bestätigt, dass die oben bezeichnete Maschine den genannten EU-Richtlinien...
  • Page 19 Notes:...

This manual is also suitable for:

174970

Table of Contents