4.2.2 Checking the Machine Condition

 Outline
This section shows the work items for understanding the machine condition at the beginning of work and solving the
current problems.
 Work items
For cleaning the sensors and covers, do not use any organic solvent, such as alcohol or Solvent Washing
Liquid.
An organic solvent can liquefy resin and paint, thus causing a machine failure or flaw in appearance.
One head is installed for 150 series
One head is installed for 150 series
© 2014 MIMAKI ENGINEERING CO.,LTD.
F/W ver
1. Upload the parameters to store the parameters of the machine.
2. When the firmware of the machine is not the latest version,
update the firmware.
3. Check the result of user's maintenance with attention paid to the
following points:
 Area around the heads
Check for ink sticking or dust accumulation. If necessary,
tell the user the cleaning method which uses Solvent
Washing Liquid or Clean Stick.
 Station
Check the areas around the caps and wipers for ink sticking
or dust accumulation. If necessary, tell the user the cleaning
method which uses Solvent Washing Liquid or Clean Stick.
 Media holder, platen, etc.
Check the following parts for paper dust accumulation or
ink sticking.
If necessary, tell the user the cleaning method which uses
natural detergent, waste cloth, or Clean Stick.
• Media Holder
• Platen
• PF Roller
• Media sensor (Two locations: back right and center)
• Cover
• Waste Ink Tank (volume of empty space)
4. Execute test drawing and check the head condition (for nozzle
clogging or jet deviation).
Perform slant adjustment and/or drop position adjustment, if
necessary.