Practical advice
General advice
The reception lens (7) and the laser beam output (8) must not
be covered during the measuring process.
The measurements are taken at the centre of the laser beam,
even when the laser is pointed at surfaces diagonally.
Errors – causes and corrective measures
Cause
Temperature warning (b) flashing, display shows "err",
measurement not possible, measuring tool switches off
automatically after five seconds
Measuring tool is outside of
the operating temperature
range of – 10 °C to +40 °C.
All symbols flash, measurement not possible
Measuring tool faulty
Fitted adapter (c) flashing, display shows "err", measure-
ment not possible
Adapter error:
– Faulty adapter
– Adapter has no connection
to the measuring tool
Bosch Power Tools
English | 35
Remedy
Wait until the measuring tool
has reached operating tem-
perature. Then switch the
measuring tool back on.
Check the batteries and re-
place them if necessary.
Send the adapter to the after-
sales service.
Clean the contacts.
If the adapter still cannot con-
nect to the measuring tool
after you have done this, send
1 609 92A 7L5 | (05.05.2022)