Victory CLASSIC Installation Manual And User's Manual

Victory CLASSIC Installation Manual And User's Manual

Professional wall-mount range hood

Advertisement

Quick Links

INSTALLATION GUIDE
AND USERS MANUAL
Professional Wall-Mount Range Hood
Installer: Leave this guide with the homeowner. Homeowner: Keep this guide for future reference.
NOTICE:
For residential use only.
www.victoryrangehoods.com
CLASSIC
Model:
Sizes:
30", 36"
PLANE
Model:
Sizes:
24", 30", 36"
Rev.20220622

Advertisement

Table of Contents
loading

Summary of Contents for Victory CLASSIC

  • Page 1 INSTALLATION GUIDE AND USERS MANUAL Professional Wall-Mount Range Hood CLASSIC Model: Sizes: 30”, 36” PLANE Model: Sizes: 24”, 30”, 36” NOTICE: For residential use only. Installer: Leave this guide with the homeowner. Homeowner: Keep this guide for future reference. www.victoryrangehoods.com...
  • Page 2: Table Of Contents

    Parts Supplied................... 8 Dimensions..................10 Preparation..................12 Rough-In.................... 13 Installation..................14 Venting Methods................18 Wiring Diagram................. 19 Range Hood Operations..............19 Troubleshooting................20 Maintenance..................21 Bulb Replacement................22 Warranty..................... 23 Disclaimer..................24 Contact Us..................24 VICTORY range hoods | CLASSIC / PLANE...
  • Page 3: Important Safety Notice

    Use high settings on cooking range only when necessary. • Never leave surface units unattended at high settings. Boil overs cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. VICTORY range hoods CLASSIC / PLANE...
  • Page 4 The manufacturer and/or distributor/reseller will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood. VICTORY range hoods | CLASSIC / PLANE...
  • Page 5: Electrical Requirements

    (at the range hood and at the junction box). Copies of the standards listed may be obtained from: * National Fire Protection Association Batterymarch Park Quincy, Massachusetts 02269 ** CSA International 8501 East Pleasant Valley Road Cleveland, Ohio 44131-5575 VICTORY range hoods CLASSIC / PLANE...
  • Page 6: Venting Requiremens

    If available, also refer to stove top manufacturer’s height clearance requirements and recommended hood mounting height above range. Minimum Duct Size: • Round - 6” * Due to different ceiling height configurations, recommended height may not be applicable. VICTORY range hoods | CLASSIC / PLANE...
  • Page 7: Calculating Duct System Length

    2 x 35W GU10 Halogen, 120V (12V LED Optional) Ducting Size Top 6” Round Warranty 1 YEAR ( parts warranty ) * Subject to change without notice, please contact your local reseller for details. VICTORY range hoods CLASSIC / PLANE...
  • Page 8: Required Tools

    Please refer to Bulb Replacement page for more information). NOTE: Where necessary, additional screws will be needed for installation and added support, but are NOT included. Please review contents before installation. VICTORY range hoods | CLASSIC / PLANE...
  • Page 9 PARTS SUPPLIED (Continued) Upper Chimney Duct Adapter Lower Chimney Plastic Flaps Ø - 6” Transition Mesh Filters (Model 24, 30 x2) (Model 36 x3) CLASSIC WALL MOUNT RANGE HOOD PLANE WALL MOUNT RANGE HOOD VICTORY range hoods CLASSIC / PLANE...
  • Page 10: Dimensions

    DIMENSIONS ( CLASSIC ) TOP VIEW Ø 6” 11 ½” Height from housing of range hood to top of transtion: 6” 13” Height from bottom of range hood to top of transtion: 16” Height from bottom of range hood to installation holes: 13 ¾”...
  • Page 11 Available sizes: 23 ½”, 29 ½” and 35 ½” FRONT VIEW SIDE VIEW 12 ¾” 11 ⅜” Chimney height adjustable from 23” to 39 ½” 12” 10 ¼” 2 ¾” 19 ¾” BOTTOM VIEW VICTORY range hoods CLASSIC / PLANE | 11...
  • Page 12: Preparation

    2. Set aside the stainless steel baffle filters and grease tunnel until the range hood is properly installed. IMPORTANT NOTE: Both CLASSIC and PLANE models have similar Rough-In and Installations. For demonstrative purposes, this manual will be using the CLASSIC model as example. VICTORY range hoods | CLASSIC / PLANE...
  • Page 13: Rough-In

    Install area for metal bracket *Due to different ceiling height configurations, *Due to different ceiling height configurations, which holds up the chimney recommended height may not be applicable. recommended height may not be applicable. VICTORY range hoods CLASSIC / PLANE | 13...
  • Page 14: Installation

    For safety purpose, pre-drilled mounting holes are provided through the back of the hood. For a more secure installation, use as many mounting holes as needed to secure from the inside of hood. VICTORY range hoods | CLASSIC / PLANE...
  • Page 15 Before connecting wires, switch power off at service panel and lock service panel to preduct power from being switched on accidentally. VICTORY range hoods CLASSIC / PLANE | 15...
  • Page 16 (5) Insert both chimneys onto the range hood. They To avoid scratching the chimney, extend the upper should be able to slide into the gap of the top housing. chimney slowly and carefully to the chimney-mounting bracket and tighten screws. VICTORY range hoods | CLASSIC / PLANE...
  • Page 17 While continuing to install the filter, ensure you depress the lever for the retractable tabs to clear way for flush insertion. When filter sits flush within the opening, release the push Tab Inserts lever to lock in place. VICTORY range hoods CLASSIC / PLANE | 17...
  • Page 18: Venting Methods

    A the hood inefficient. Use a smooth elbows. Use 45 degrees reducer will reduce the CFM of elbow to guide the air outdoors. instead, if possible. the hood and increase the noise. VICTORY range hoods | CLASSIC / PLANE...
  • Page 19: Wiring Diagram

    • Press the Light Switch to power on the lights. Turn Off: • Press the Power Switch to turn off the power. • Press the Light Switch to power off the lights VICTORY range hoods CLASSIC / PLANE | 19...
  • Page 20: Troubleshooting

    NO reducers or plenums in the duct work. • Refer to Duct Venting in the Venting Methods page for illustrative examples. NOTE: For all other inquiries, please contact Victory Range Hoods. VICTORY range hoods | CLASSIC / PLANE...
  • Page 21: Maintenance

    Dry filters and re-install before using hood. Replacing Filters: • Should filters wear out due to age and prolonged use, please contact Victory Range Hoods to order • Note: Also replace damaged filter that has punctured or broken mesh, bent or broken frame.
  • Page 22: Bulb Replacement

    6. Reverse the steps to install a new halogen light fixture 7. Turn ON breaker and range hood to test for operation. Light Housing Power Plug Hood Panel Flat-head Screwdriver Metal Clip NOTE: For all other inquiries, please contact Victory Range Hoods. VICTORY range hoods | CLASSIC / PLANE...
  • Page 23: Warranty

    Victory Range Hoods. The information in this document is subject to change without notice, please contact Victory Range Hoods for updated details. VICTORY range hoods...
  • Page 24: Disclaimer

    583 Nicola Avenue, Port Coquitam, BC, Canada Toll Free: 1-800-394-4020 info@victoryrangehoods.com The information in this document is subject to change without notice, please contact Victory Range Hoods for updated details. VICTORY range hoods | CLASSIC / PLANE...
  • Page 25 NOTES VICTORY range hoods CLASSIC / PLANE | 25...
  • Page 26 583 Nicola Avenue | Port Coquitlam | BC | Canada | V3B 0M3 www.victoryrangehoods.com...

This manual is also suitable for:

Plane

Table of Contents