Page 1
INSTALLATION GUIDE AND USERS MANUAL CEILING - MOUNT RANGE HOOD HORIZON Model Name: READ AND SAVE THESE INSTRUCTIONS For residential use only. Installer: Leave this guide with the homeowner. Homeowner: Keep this guide for future reference. Rev.20240730...
IMPORTANT SAFETY NOTICE Read all instructions before installing and operating this appliance • The installation in this manual is intended for quali ed installers, service technicians or persons with similar quali ed background. Installation and electrical wiring must be done by quali ed professionals and in accordance with all applicable codes and standards, including re-rated construction.
Page 4
The manufacturer and/or distributor/reseller will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood. | HORIZON...
ELECTRICAL REQUIREMENTS IMPORTANT: Observe all governing codes and ordinances. It is the customer’s responsibility: • To contact a quali ed electrician • To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 — latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.
• If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible. Minimum Duct Size: • Round - 8". Use Aluminimum foil tape to properly seal. | HORIZON...
CALCULATING VENT SYSTEM LENGTH To calculate the length of the duct system you require, subtract the equivalent feet for each “Vent piece” (Table Below) used in the system from the “Recommended maximum run” (Table Below). The longest duct run that is acceptable (if completely straight) is 50 feet. The number of vent pieces (elbow, transition, etc.) installed in your duct run will determine the maximum length the duct run can be.
REQUIRED TOOLS Putty Drywall Pencil Utility Power Knife Knife Knife Drill Tape Phillips Measure Screwdriver Level Aluminum Tape PARTS SUPPLIED (No Lights) | HORIZON...
Page 9
PARTS SUPPLIED (Continued) With Lights: Magnetic Metal Plate HORIZON | 9...
Page 10
PARTS SUPPLIED (Continued) NOTE: Where necessary, additional screws might be needed for installaton and , t r " Please review contents before installation. Washer Main Support Brackets HORIZON Range Hood Mesh Filter (x3) | HORIZON...
DO NOT CLOSE THE BOX AROUND THE HOOD UNTIL THE TEST HAS BEEN PERFORMED. Victory Range Hoods Inc. will not be responsible for additional labour costs related to reinstallation of the hood due to transportation internal damage or wiring issues.
ROUGH - IN Orientation of Joists Orientation of Joists the joists. must match island stove must match island stove " Cut-Out Please NOTE: The orientation of the joists and the orientation of the stove must i s t match. ⁄ " If the orientation does not match, the range hood may need to be dropped down into a a l l...
Page 14
INSTALLATION (Continued) Installation Holes Fasten one M6 screw with washer onto middle screw hole per MAIN SUPPORT BRACKETS to the range hood as shown below. Washer | HORIZON...
Page 15
INSTALLATION (Continued) IMPORTANT: You will need to gain access to the internal area of the ceiling to mount and secure connection of the top duct to the transition opening as the range hood slides un between the joists. SIDE VIEW 8"...
Page 16
Use aluminum tape foil to secure vent connections (2) Fasten the M6 Bolts with washers to the Main Support Brackets and range hood. (3) Fasten woodscrews through the main top brackets and onto the joists. SIDE VIEW SIDE VIEW Installation holes | HORIZON...
Page 17
INSTALLATION (Continued) Remove the side panels in order to gain access to the installation holes. Use woodscrews at the corner installation holes of the range hood to fasten to the joists for additional support. Re-install the side panels.
DO NOT use REDUCERS. Keep the size of the duct the same, as per the manual. A reducer will reduce the CFM of the hood and increase the noise. c. DO NOT use plenum boxes. Boxes create turbulence and make the hood Use a smooth elbow to guide the air outdoors. | HORIZON...
VENTING METHOD • The range hood should be placed at a maximum distance of about 8’ from • This range hood comes only with a top 8" duct option. • Vent work can terminate either through the roof or wall. 8"...
*The wall switch may slightly vary *IMPORTANT NOTICE* The wiring of the range hood must be performed by a CERTIFIED ELECTRICIAN VICTORY Range Hoods is not responsible for any damages due to improper connection. 14-3 and 14-2 (Cables not included)
Page 21
Capacitors Capacitors Capacitors Cover Panel Cover Panel Cover Panel *IMPORTANT NOTICE* Wiring of the range hood must be performed by a CERTIFIED ELECTRICIAN VICTORY Range Hoods is not responsible for any damages due to improper connection. HORIZON | 21...
Page 22
FRONT PANEL SWITCH* *The wall switch may slightly vary ***IMPORTANT NOTICE*** wiring range hood must be performed by CERTIFIED ELECTRICIAN . VICTORY Range Hoods is not responsible for any damages due to improper connection. 14-3 Cables (Not included) 14-2 Cable (Not included)
Page 23
Cables from motor C C apacitors Capacitors C C over Panel Cover Panel *IMPORTANT NOTICE* Wiring of the range hood must be performed by a CERTIFIED ELECTRICIAN VICTORY Range Hoods is not responsible for any damages due to improper connection.
The duct size must be 8”, or larger. Please make sure there are NO reducers or plenums in the duct work. • Refer to ‘Do's and Don'ts for Duct Venting’ page for illustrative examples. NOTE: For all other inquiries, please contact Victory Range Hoods. | HORIZON...
Dry the filters and re-install before using the hood. Replacing Filters: • Should filters wear out due to age and prolonged use, please contact Victory Range Hoods to order replacement filters. NOTE: For all other inquiries, please contact Victory Range Hoods.
This Warranty Will Be Voided When: follow installation instructions. When product is used commercially or other than its intended What is Not Covered: The information in this document is subject to change without notice, please contact Victory Range Hoods for updated details. | HORIZON...
583 Nicola Avenue, Port Coquitam, BC, V3B 0M3, Canada Toll Free: 1-800-394-4020 info@victoryrangehoods.com The information in this document is subject to change without notice, please contact Victory Range Hoods for updated details.
Page 28
583 Nicola Avenue | Port Coquitlam | BC | V3B 0M3 Canada www.victoryrangehoods.com...
Need help?
Do you have a question about the HORIZON and is the answer not in the manual?
Questions and answers