After installing the M.2 backplane, complete the following steps:
1. Reinstall the PCIe riser card if necessary (see
2. Reinstall the LOM adapter if necessary (see
3. Install the PCIe expansion tray (see
4. Install the top cover (see
5. Reconnect the power cords and any cables that you removed.
6. If the server is installed in a rack, reinstall the server into the rack.
7. Power on the server and any peripheral devices.

Install the chassis air baffle

Use this procedure to install the chassis air baffle.
Before installing the chassis air baffle:
1. Read the safety information and installation guidelines (see
Guidelines" on page
To install the chassis air baffle, complete the following steps:
Watch the procedure
A video of this procedure is available at YouTube:
PLYV5R7hVcs-Ak9fT8QAx8fLbEivizjRtp
Figure 89. Chassis air baffle installation
Step 1.
Align the chassis air baffle with the slots on both sides of the chassis, and lower it into the server.
Step 2.
Slightly press the chassis air baffle, make sure it is fully secured.
After installing the fan cage assembly, complete the following steps:
"Install the LOM adapter" on page
"Install the PCIe expansion tray" on page
"Install the top cover" on page
56).
.
"Install the PCIe riser card assembly" on page
128).