Chapter 19. Myrinet 2000; Myrinet Pci Board; Myrinet Switch Chassis; Myrinet Chassis Sizes And Capacities - IBM Cluster 1350 Installation And Service

Hide thumbs Also See for Cluster 1350:
Table of Contents

Advertisement

Chapter 19. Myrinet 2000

Contents
The 2-Gbit Myrinet Switch is a customer option that provides high-speed
communication between the Storage Nodes and Cluster Nodes, over an optical
cable. It requires a Myrinet Switch chassis in the Primary Cabinet and a Myrinet
PCI adapter in each Storage Node and Cluster Node.

Myrinet PCI board

The Myrinet PCI board resides in the Cluster (x335) and Storage (x345, x360)
Nodes. Use the installation procedures in the appropriate server's documentation
to replace a Myrinet PCI board.
The GM software for running the Myrinet board should already reside on the
Cluster and Storage Nodes, so no new installation of software should be required
when a Myrinet PCI board is replaced.

Myrinet switch chassis

The Myrinet Switch contains the following replaceable components:
8-port line card
Management Module
Blower module
All of these components can be hot-swapped. The Myrinet documentation
discusses installation of these components.
The three Myrinet Chassis sizes available are described in Table 21.
If the backplane fails in the Myrinet Switch, you must replace the entire Switch
chassis. Use the following steps to replace the chassis:
1. Ensure that the cluster is not running critical applications.
2. If the optical cables connected to the Switch are not labeled, place labels on the
© Copyright IBM Corp. 2003
Provides the connections to the Storage and Cluster Nodes. The line cards
plug into slots in the Switch chassis.
Manages and routes the Myrinet traffic, polling the ports and building
tables to control the addressing of messages.
Cools the Myrinet Switch Chassis
Table 21. Myrinet Chassis Sizes and Capacities
Slots in Switch
Line Cards
5
1-4
9
1-8
17
1-16
cables so they can be located to their respective connectors when the new
chassis is installed.
Nodes Supported
EIA Slots Consumed
4-32
4
4-64
6
4-128
10
109

Advertisement

Table of Contents
loading

Table of Contents