Chapter 8. Troubleshooting - Renesas Emulation Pod forM16C/20 Series M30200T-RPD-E User Manual

Emulation pod form16c/20 series
Table of Contents

Advertisement

Chapter 8. Troubleshooting

When the M30200T-RPD-E does not work properly, check the items listed below.
(1) The emulator main unit cannot be powered up.
(2) The M30200T-RPD-E does not start up when the target system is connected with the PC4701
When the condition does not improve even if you check the items above, troubles described below
are considered.
Check to see if the AC power cord is firmly plugged into the receptacle.
Check to see if the AC power 3P-2P converting connector is firmly connected.
system. (The Error LED of the emulator main unit lights up.)
Check (1) described above.
Check whether the emulator main unit and the FLX120-RPD are firmly connected.
Check whether the FLX120-RPD and the M30200T-RPD-E are firmly connected.
Check whether the M30200T-RPD-E and the pod probe are firmly connected.
Check whether the converter board and the target system are firmly connected.
Check whether the power and GND are supplied to the target system.
Check whether switches of the pod probe are properly set. (For details, refer to the user's manual
of the pod probe.)
Check whether the RESET pin is held 'HIGH' when the target system is connected.
Check whether the oscillator circuit of the target system is oscillating correctly when using the
oscillator of the target system.
Check whether proper firmware is downloaded in the emulator main unit. (Refer to the user's
manual of the emulator debugger about how to download firmware.)
(1) Trouble of the evaluation MCU
(2) Trouble of the M30200T-RPD-E
(3) Trouble of the PC4701 emulator main unit
( 29 / 32 )

Advertisement

Table of Contents
loading

Table of Contents