Table of Contents

Advertisement

Troubleshooting

Disruptions
Causes
Incorrect comb assembly
Significant abnormal
Incorrect comb tightening
vibrations
Vibrating head wear
Broken carbon rod
Wear
Noise in the extension
Extension guide damaged
Battery discharged
No power supply
The machine will not start
Other
Too much pressure on the branches
Unexpected machine
stoppages
Battery discharged
Solutions
Refit the comb using the procedure.
Re-tighten the comb.
Check the gap on the ball and socket
and contact the dealer if necessary.
Replace the broken rod.
Contact your dealer.
Recharge the battery
Re-connect the machine.
Contact your dealer.
Use a top to bottom comb movement
on the tree.
Recharge the battery.
15
NOTe :
16

Advertisement

Table of Contents
loading