Nidek Medical Max 30 3005 Instructions For Use Manual

Nidek Medical Max 30 3005 Instructions For Use Manual

Oxygen concentrator

Advertisement

Quick Links

INSTRUCTIONS FOR USE
Max 30
OXYGEN CONCENTRATOR
For models: 3005 and 3010
(and variants thereof)
[Original language is English]
This unit is not a life-support device. Geriatric,
pediatric, or any other patient unable to
communicate discomfort while using this device
should receive additional monitoring.
This device supplies highly concentrated oxygen
enriched product gas that promotes rapid
burning.
DO NOT allow smoking or open flames within the
same room of this device or the administration
accessory (cannula). Failure to observe this
warning can result in severe fire, property
damage, and / or cause physical injury or death.
Oxygen accelerates the combustion of flammable
substances. DO NOT use oil, grease, petroleum
based or other flammable products on the
device, the administration accessory (cannula) or
the patient's face / neck.
Only persons who have read and understood this
entire manual should be allowed to operate the
device.
CONTRAINDICATIONS - Those who continue to
smoke (because of the increased fire risk and the
probability that the poorer prognosis by smoking
will offset the treatment benefit).
Federal Law (US) restricts this device to sale by, or
on the order of, a licensed physician. This oxygen
Only
concentrator should be used only under the
supervision of a licensed physician.
______________________________________________________________________________________________________________
2010-9801CE-D
Contents
1
GLOSSARY OF SYMBOLS ................... 2
2
YOUR DEVICE ....................................... 2
2.1
2.2
Device Features ................................. 2
2.3
2.4
Specifications ............................................... 3
2.5
3
4
4.1
Installation ......................................... 4
4.2
Start-Up ............................................. 5
4.3
Shut Down ......................................... 5
5
5.1
Cleaning ............................................ 5
5.2
Maintenance ...................................... 5
6
DISPOSAL ............................................... 6
6.1
Method for Waste Disposal ............... 6
6.2
Disposing of the Device .................... 6
7
TROUBLESHOOTING ........................... 6
8
EMC INFORMATION............................. 7
9
March 2022
EN
Page 1 of 8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Max 30 3005 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Nidek Medical Max 30 3005

  • Page 1 INSTRUCTIONS FOR USE Max 30 OXYGEN CONCENTRATOR For models: 3005 and 3010 (and variants thereof) [Original language is English] This unit is not a life-support device. Geriatric, Contents pediatric, or any other patient unable to communicate discomfort while using this device GLOSSARY OF SYMBOLS ....
  • Page 2 GLOSSARY OF SYMBOLS The Max 30 concentrators begin their operation with air being pulled into the external air intake filter. This filtered air enters the compressor via a suction resonator ON (Power switched on) and fine filter. Pressurized air then exits the compressor and passes through a heat exchanger, which reduces the OFF (Power switched off) temperature of the compressed air.
  • Page 3 Thermal safety: The compressor motors (4) are Use the power cord provided. Check that the electrical characteristics of the power protected by a thermal switch situated in the stator outlet used match those indicated on the manufacturer’s winding (145 ± 5° C). plate on the rear panel of the device.
  • Page 4 The Oxygen Concentrator is packaged to protect the requirements. device from damage while being transported and stored. The accessories below, available from Nidek Medical After the device is removed from the package, inspect Products, Inc. and our distributors, comply with these for damage.
  • Page 5 Shut Down We recommend against the use of extension cords and adapters, as they are potential sources of sparks and fire. At the end of the treatment, press the Stop Button (Fig. 1-2) to shut the device down. If the device will not be ...
  • Page 6 DISPOSAL Preventive Maintenance Wash the cabinet filters (3) weekly or after approximately 100 hours of use and for Method for Waste Disposal each patient. More frequent cleaning recommended in dusty environments. Inspect inlet air All waste from the device (Patient Circuit, Molecular filters (3) during each service.
  • Page 7 INFORMATION ______________________________________________________________________________________________________________ 2010-9801CE-D March 2022 Page 7 of 8...
  • Page 8 CB and other portable devices, microwave ovens, induction plates or even remote control toys or any other electromagnetic interferences which exceed the levels specified by the EN 60601-1-2 standard. Nidek Medical Products, Inc. 3949 Valley East Industrial Drive Birmingham, Alabama 35217 U.S.A.

This manual is also suitable for:

Max 30 301030053010

Table of Contents