3.2.3.

Device Redundancy

The backup device shows the status of all monitored devices on the front page. If there are failures on devices, then this is
displayed in the Status column.
No data rates for inputs and outputs are displayed for the backup device. The initialisation pages (Phase1 - Phase3) are not
available.
The device redundancy can be tested by clicking the Replace button for each individual monitored device.
In case any monitored device fails, redundant device detects the failure, disables the failing device and starts replacing it. The
reason is shown in the Status column.
After the backup device has replaced another device, other devices are no longer monitored.
Therefore, the failed device should be repaired or replaced as soon as possible.