4.11. Redundancy

4.11.1. Input port redundancy

Under the menu item MAINTENANCE > REDUNDANCY, you can configure whether and how the CAS interface is used as an IPTV
input or as a redundant IPTV input.
CAS port usage:
 Choose CAS.
The CAS interface is used as CAS interface.
 Choose IPTV2.
The CAS interface is used as second IPTV input.
Minimum data rates:
The minimum valid input data rate and the minimum valid output data rate apply to the NMS function.
If the values are fallen short of, then the system switches to the backup device.
The minimum input/output data rates must be configured for each device to be monitored. The values can be different for each
monitored device.

4.12. NMS (with MIS 1-11)

A device can monitor up to five other devices and serve as a backup device for these devices. If certain configurable conditions
apply (input error, output error, operating voltage error, etc.), then the backup device is switched to.
Switching is only done if the backup device does not also fail. Switching will not occur, for example, if the IPTV input is missing on
both devices or both are connected to the same failed power source.