Step 3: Low Voltage Transformer Wiring
Refer to the wiring diagram below for Hayward 300W transformers. For other transformers, refer to
the instructions. Be sure to follow all NEC and local codes when wiring.
Use 14V tap
(blue)
Ground
(green)
Hot
Connection
(black)
Neutral
Connection
(white)
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Bonding
Wire
From power control
To junction box / LED light
L1 & L2 low voltage
connections