CONTROL-1500A Single Axis Antenna Controller
POS
DATA DELETED
4.8

FIX Mode

POS
SELECT SATELLITE
GALAXY 6
The FIX feature allows the position of a satellite stored in non-volatile memory to be loaded
into the controller's current position counter. This feature is useful if a faulty position sensor or
a noise impulse results in an errant position count.
1. While in MANUAL mode, jog the antenna to a satellite whose location was previously
stored in memory. Use a Ku band satellite if the antenna can receive both C and Ku band.
2. Proceed to FIX mode.
3. Scroll through the list of assigned satellites (in alphabetical order) until the correct satellite
name is displayed.
4. Press the ENTER key. The system will respond with the following message for a few
seconds and proceed to manual mode.
POS
POSITION FIX
ACCOMPLISHED
5. With an assistant out at the antenna, validate the accuracy of the limits by moving the
antenna to both limit positions.
4.9

CONFIG Mode

Config mode allows the user to view and/or modify various controller parameters and to enable
or disable certain features. When this mode is active, the SCROLL keys may be used to
select various items for either viewing or modification. The BKSP (backspace) key is active. To
change the value of a parameter, the user can simply key in a new value and press ENTER for
the change to take effect and update the parameter's value in the controller's non-volatile
memory. If the present value of the parameter is invalid, '*' characters will be displayed in the
item's data field. If the user terminates a data entry with the ENTER key and the value is
accepted, the next Config mode item will be displayed. If the user terminates a data entry with
the ENTER key and the data is not accepted, the Config mode item will not change. The
MODE key can be pressed at any time to exit Config mode.
Access to certain Config mode items can be restricted depending on the status of the Expert
Access flag and by the values currently assigned to certain Config mode items. When the
Expert Access flag is reset (see section 2.5), the only Config mode items which will be
DAWNco • 3340 S. Lapeer Rd • Orion, MI 48359-1320 • Ph (248) 391-9200 • Fax (248) 391-9207 • sales@DAWNco.com
POL
SS
DEL
MODE
POL
SS
FIX
MODE
POL
SS
MODE