Site Preparation
Electrical Requirements
CAUTION
The outlet must be checked by a qualified electrician
to be sure it is wired with the correct polarity. Verify
the outlet is properly grounded (earthed).
WARNING
If the supply cord is damaged, it must be replaced
with a special cord or assembly available from the
manufacturer or its service agent.
WARNING
Do not use an extension cord, two-prong adapter, or
remove the power cord ground prong.
Electrical
Shock
Hazard
Plug power cord directly into a properly
grounded (earthed) outlet.
Do not defeat the grounding (earthing)
nature of the plug.
Do not use adapter or extension cord.
Failure to follow these instructions could
cause serious injury or death.
See installation instructions
4 | English
Preparation
Uncrate the unit and inspect for damage. Remove the
wood base and discard the shipping bolts and brackets.
Remove and recycle packing materials. Do not discard the
kickplate, anti-tip bracket, and hardware.
Remove the kickplate by extracting the two mounting
screws. Refer to the illustration below.
SCREW
Kickplate removal